ZUP120-1.8/U TDK Corporation, ZUP120-1.8/U Datasheet - Page 39

PWR SUP BENCH PROG 0-120V 216W

ZUP120-1.8/U

Manufacturer Part Number
ZUP120-1.8/U
Description
PWR SUP BENCH PROG 0-120V 216W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP120-1.8/U

Load Regulation
0.01%
Voltage - Output
0 ~ 120V
Number Of Outputs
1
Power (watts)
216W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 120 VDC @ 1.8A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
216W
Operating Temperature
0°C ~ 50°C
Efficiency
82%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
120V
Output Current
1.8A
Power Rating
216W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 70 mV
Brand/series
ZUP
Current, Output
1.8 A
Display Type
Digital Meter
Power, Output
216 W
Power, Rating
216 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
80 mV @ 20 MHz BW
Voltage, Output
120 VDC
Voltage, Ripple
30 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1671
ZUP1201.8/U
4.4.13 Auto Parallel Operation
1.Up to five units of the same rating can be connected in an auto-parallel combination to provide up to
2. Foldback protection if desired, may only be used with the master unit. When the master unit shuts
3. Setting the voltage and current:
4.While operating in CV mode, the master unit regulates the output voltage and the slave units operate
5. Over Voltage Protection:
6. Connection to the Load:
parallel units. During operation, the master unit operates at CV mode and the slave units at CC mode.
five times the output current capability. One of the power supplies operates as a master and the
remaining units as slaves. The slave units are analog programmed by the master unit. At remote
operation, only the master unit can be programmed by the computer while the slave units may be
connected to the computer for actual voltage and current readback only.
down it programs the slave units to zero output voltage.
The output voltage of the slave units should be programmed higher than the output and the master to
avoid interference with the master CV control. Output voltage of the master should be programmed
to the desired voltage, and the current limit to the desired load current divided by the number of
as controlled current source, following the master output current. It is recommended to design the
power system so that each unit will supply up to 95% of it’s current rating, because of an imbalance
which may be caused by cabling and connections voltage drop.
OVP of the slave units should be adjusted higher than the Master OVP. When the master unit shuts
down, it programs the slave units to zero output voltage. If a slave unit shuts down (when it’s OVP is
set lower than the master output voltage), only that unit will shut down and remaining slave units
will supply all the load current.
sensing. Refer Fig. 4-9, 4-10 & 4-11 for typical connections of paralleled power supplies. The figure
below shows connection of two units, however the same connection method applies for up to 5 units.
resistance should be as close as possible to achieve current balance between power supplies.
COM
VCVP
VCCP
RCCP
COM
VCVP
VCCP
RCCP
With local sensing it is important to minimize the wire length and resistance. Also the wires
- S
+S
- S
+S
P
P
2
2
14
14
13
13
1
1
On/Off
Output Good
VRFV
VRFI
RCVP
- LS
+LS
Output Good
On/Off
VRFV
VRFI
RCVP
- LS
+LS
At auto-parallel mode, power supplies can be connected in local or remote
The master unit OVP should be adjusted to the desired OVP level. The
MASTER
SUPPLY
POWER
SUPPLY
POWER
SLAVE
NOTE
- V
+V
- V
+V
Fig. 4-9: Auto-parallel with local sensing
(ZUP rear panel view)
+
_
LOAD