ZUP120-1.8/U TDK Corporation, ZUP120-1.8/U Datasheet - Page 42

PWR SUP BENCH PROG 0-120V 216W

ZUP120-1.8/U

Manufacturer Part Number
ZUP120-1.8/U
Description
PWR SUP BENCH PROG 0-120V 216W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP120-1.8/U

Load Regulation
0.01%
Voltage - Output
0 ~ 120V
Number Of Outputs
1
Power (watts)
216W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 120 VDC @ 1.8A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
216W
Operating Temperature
0°C ~ 50°C
Efficiency
82%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
120V
Output Current
1.8A
Power Rating
216W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 70 mV
Brand/series
ZUP
Current, Output
1.8 A
Display Type
Digital Meter
Power, Output
216 W
Power, Rating
216 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
80 mV @ 20 MHz BW
Voltage, Output
120 VDC
Voltage, Ripple
30 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1671
ZUP1201.8/U
3. Series connection for bipolar output voltage:
the current limits of each power supply to the maximum that the load can handle without damage. It is
recommended to connect diodes in parallel to each unit output to prevent reverse voltage during start-
up condition or in case one of the units shuts down. Each diode should be rated to at least the power
supply’s output current. Refer to Fig. 4-14 for this operating mode.
3.1 General: At this operation mode, two units are configured as a bipolar voltage/current source. Set
3.2 Remote programming at series operation for bipolar output voltage:
1. Programming by external voltage; The analog programming circuits of the ZUP power supply
2. Programming by external resistor: Programming by external resistor is possible. Refer to
3. Programming via the communication port (RS232/RS485): The communication port is isolated
are referenced to the - Sense potential. Therefore, the circuits used to control each unit must
be separated and floated from each other.
Fig. 4-5 and Fig. 4-6 for details.
from the output voltage, therefore the serialy connected power supplies can be chained using
the Remote-In and Remote-Out connectors.
Fig. 4-14: Series connection for bipolar output
SUPPLY
SUPPLY
POWER
POWER
- LS
- LS
+LS
+LS
- S
- S
+S
+S
+
_
+
_
COM
+
_
LOAD

Related parts for ZUP120-1.8/U