MAP130-4010 POWER ONE, MAP130-4010 Datasheet - Page 2
MAP130-4010
Manufacturer Part Number
MAP130-4010
Description
QUAD OUTPUT SWITCH PW SP 130WATT
Manufacturer
POWER ONE
Series
MAP130r
Type
Commercial, Industrialr
Datasheet
1.MAP130-1012.pdf
(4 pages)
Specifications of MAP130-4010
Voltage - Output
±5V, ±12V
Number Of Outputs
4
Power (watts)
130W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
115 ~ 230VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 20A
2nd Output
12 VDC @ 5A
3rd Output
-5 VDC @ 1A
4th Output
-12 VDC @ 3A
Size / Dimension
8.5" L x 4.5" W x 2" H (215.9mm x 114.3mm x 50.8mm)
Power (watts) - Rated
130W
Operating Temperature
0°C ~ 50°C
Efficiency
80%
Approvals
CE, CSA, EN, TUV, UL
Line Regulation
0.2%, 0.5%
Load Regulation
1%, 2%
Product
Switching
Brand/series
MAP130 Series
Configuration
Open-Frame
Current, Input
3.3 A (RMS) @ 90 VAC
Current, Leakage
700 μA (Max.)
Dimensions
8.50 in. L x 4.50 in. W
Hold Time
40 ms (Min.)
Operation
Switching
Output
-12 VDC @ 3 A, -5 VDC @ 1 A, +5 VDC @ 20 A, +12 VDC @ 5 A
Power, Output
130 W
Power, Rating
130 W (Continuous)
Primary Type
AC-DC
Special Features
Power Fail, Remote Sense
Temperature, Operating
50 °C
Voltage, Input
115/230 VAC
Voltage, Output
-12, -5, +5, +12 VDC
Voltage, Output 1
-5 V
Voltage, Output 2
-12 V
Voltage, Output 3
12 V
Voltage, Output 4
24 V
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Output Current (max)
20/5/1/3A
Input Voltage
90 to 132/175 to 264V
Output Voltage
5/12/-5/-12V
Output Power (max)
130W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
215.9mm
Product Height (mm)
50.8mm
Product Depth (mm)
114.3mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Surface Mount
Pin Count
15
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
Q549907
Multiple Output Model Selection (Cont.)
NOTES: 1) Peak loads up to 165 Watts, (total of all outputs), for 60 seconds or less are acceptable, (10% duty cycle max.).
Input Specifications
PARAMETER
Input Voltage- AC
Input Frequency
Brown out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
Output Specifications
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot /Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
MCD10115 Rev. 1.3, 05-Feb-10
MODEL
MAP130-4003
MAP130-4004
MAP130-4010
MAP130-4020
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
VOLTAGE
OUTPUT
+15V
+24V
+15V
+12V
+12V
-15V
-15V
-12V
-12V
+5V
+5V
+5V
+5V
-5V
-5V
-5V
4.75V to 5.50V
14.0V to 16.0V
4.75V to 5.50V
23.0V to 25.0V
4.75V to 5.50V
11.5V to 12.8V
4.75V to 5.50V
11.5V to 12.8V
ADJUSTMENT
CONDITIONS/DESCRIPTION
Auto-ranging.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC input voltage (115 VAC).
90 VAC, 130W load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264 VAC (one cycle). 25° C.
Switching frequency of main transformer (variable).
CONDITIONS/DESCRIPTION
Full Load, 115VAC. Varies with distribution of loads among outputs.
MAP130-1012.
MAP130-1024.
MAP130-1005 and all multiple output models, main channel only.
Full load, 20MHz bandwidth.
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple output models.
Output voltage overshoot/undershoot at turn-on / turn-off
Varies by output, Total regulation includes: line changes from 90-132 VAC
or 175-264, changes in load starting at 20% load and changing to 100% load.
Recovery time to within 1% of initial set point due to a 50-100% load change,
4% max. deviation. (Main output only on multi-output units)
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
CURRENT
OUTPUT
3.5A
20A
20A
20A
20A
4A
1A
1A
1A
1A
5A
1A
3A
5A
1A
3A
–
130W Continuous Output Power
Page 2 of 4
PEAK CURRENT
(NOTE 1)
30A
30A
30A
10A
30A
10A
8A
1A
1A
5A
1A
1A
1A
3A
1A
3A
MAP130 AC-DC Series Data Sheet
REGULATION
0.2%
0.5%
0.5%
0.5%
0.2%
0.5%
0.5%
0.5%
0.2%
0.5%
0.5%
0.5%
LINE
1%
1%
2%
2%
Low Range
High Range
130W load:
Range:
REGULATION
LOAD
1%
2%
2%
2%
1%
2%
2%
2%
1%
2%
2%
2%
1%
2%
2%
2%
1.25
0.63
3.00
175
MIN
MIN
90
47
90
40
16
71
See Model Selection Chart
See Model Selection Chart
NOISE %p-p (NOTE 2)
TYPICAL RIPPLE &
NOM
115
230
NOM
3.3
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
www.power-one.com
MAX
132
264
120
MAX
130
165
500
63
38
80
20
-14.7V to -15.3V
-14.5V to -15.5V
-11.6V to -12.4V
-11.6V to -12.4V
11.75V to 12.0V
11.75V to 12.0V
1
2
15.0V to 15.1V
23.9V to 24.1V
14.5V to 15.5V
INITIAL SETTING
-4.8V to -5.2V
-4.8V to -5.2V
-4.8V to -5.2V
5.15V to 5.2V
5.1V to 5.25V
5.1V to 5.25V
5.1V to 5.2V
ACCURACY
Amps
Watts
UNITS
UNITS
A
VAC
VAC
mS
A
kHz
Sec
mS
µS
Hz
RMS
%
%
PK