S82Y-J10F Omron, S82Y-J10F Datasheet - Page 18

no-image

S82Y-J10F

Manufacturer Part Number
S82Y-J10F
Description
MOUNTNG BRAKT FRONT FOR S82J-100
Manufacturer
Omron
Series
S82Jr
Datasheets

Specifications of S82Y-J10F

Accessory Type
Mounting Bracket(s)
For Use With/related Products
S82J 100W Power Supplies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
S82YJ10F
Safety Precautions
Refer to Safety Precautions for All Power Supplies.
■ Precautions for Safe Use
Mounting
To improve and maintain the reliability of the Power Supply over a
long period of time, adequate consideration must be given to heat
radiation.
The Power Supply is designed to radiate heat by means of natural
air-flow. Therefore, mount the Power Supply so that air flow takes
place around the Power Supply.
When mounting the Power Supply, mounting it to a metal plate is
recommended.
When mounting two or more Power Supplies side-by-side, allow at
least 20 mm spacing between them, as shown in the following
illustration.
Forced air-cooling is recommended.
Mounting Methods
The following mounting methods are available.
10-/25-/50-/100 (24-V Output)-W Models
(A) Side mounting
(B) Bottom mounting
(C) Front mounting (see Accessories)
Note: Refer to the section on the Mounting Bracket.
Minor electric shock, fire, or Product failure may
occasionally occur. Do not disassemble, modify, or repair
the Product or touch the interior of the Product.
Minor burns may occasionally occur. Do not touch the
Product while power is being supplied or immediately
after power is turned OFF.
Fire may occasionally occur. Tighten terminal screws to
the specified torque 0.74 N·m for 10-, 25-, 50-, or 100-W
models (24-V output); or 1.08 N·m for 100- (5-, 12-, or 15-
V output), 150-, 300-, or 600-W models.
Minor injury due to electric shock may occasionally occur.
Do not touch the terminals while power is being supplied.
Minor electric shock, fire, or Product failure may
occasionally occur. Do not allow any pieces of metal or
conductors or any clippings or cuttings resulting from
installation work to enter the Product.
!CAUTION
20 mm min.
(B)
Air
Metal plate
(A)
100 (-5, -12, -15 V Output)/150-/300-/600-W
Models
The following 4 mounting methods are possible.
(A) Side mounting
(B) Bottom mounting (secured with screws from the inside of the
(C) Bottom mounting (secured with screws from the back of the
(D) Front mounting
Wiring
Connect the ground completely. Electric shock or malfunction may
occur if the ground is not connected completely.
Tighten terminal screws to the following specified torque.
Do not apply more than 75-N force to the terminal block when
tightening it.
10-, 25-, 50-, or 100-W (24 V)
100-W (5-, 12-, or 15-V), 150-, 300-, 600-W M4
Switching Power Supply) (except for 300- and 600-W models)
Switching Power Supply)
Front mounting is possible with the mounting brackets provided.
Refer to Dimensions on page 11.
Capacity
Mounting brackets
(provided)
(C)
(B)
Metal plate
M3.5
(A)
Terminal
screws
S82J
0.74 N·m
1.08 N·m
Torque
18