IS-DEV KIT-7 NKK Switches, IS-DEV KIT-7 Datasheet - Page 7

KIT DEV FOR OLED SWITCH

IS-DEV KIT-7

Manufacturer Part Number
IS-DEV KIT-7
Description
KIT DEV FOR OLED SWITCH
Manufacturer
NKK Switches
Series
SmartSwitch™r
Datasheet

Specifications of IS-DEV KIT-7

Main Purpose
Switches with Programmable Display
Embedded
Yes, ASIC
Utilized Ic / Part
ISC15ANP4
Primary Attributes
2 OLED Switches, PC Board with Flash Memory
Secondary Attributes
Power and Programming Connections
Description/function
SMARTSWITCH Development Kit
For Use With
360-2431 - SERIAL CBL RJ11-DB9 FOR DEV KIT360-2430 - POWER SUPPLY 240VAC FOR DEV KIT360-2429 - POWER SUPPLY 120VAC FOR DEV KIT
Lead Free Status / RoHS Status
Not applicable / Not applicable
For Use With/related Products
Smart Switch - OLED
Other names
360-2339
7850 East Gelding Drive • Scottsdale, AZ 85260-3420
4. Operational Details
Power-Up Sequence (Steps 1,2,3)
Upon power-up or reset, controller performs the following steps:
Step 1: Check the status of Mode Select Switch for mode of operation. Initialize according to selected mode.
Step 2: Display dim and bright on the two switches and allow for adjustments of the brightness. There are 16
brightness levels (0 to F). When the internal timer is expired, the controller proceeds to Step 3. Every time a
switch is pressed, the timer gets reset. If a switch is held depressed the timer does not run. Switch activity are
not reported to host.
Step 3: Transmit 11H to host via RS232. Check the microSD for set up value. If set up values are
programmed, get the start address for switch 1, start address for switch 2 and the flag byte. If the set up values
are not programmed use the default values: start address for switch 1 = current address for switch 1 = 0001H,
start address for switch 2 = current address for switch 2 = 0010H and flag byte = 80H.
Step 4:
Step 5: Send the pictures from microSD to OLED module according to start addresses.
Main Operational Mode
Step 6:
CL01 Intelligent Controller Users Manual B.doc
A. If attributes for start address of switch 1 are programmed, get the attribute for switch 1.
B. If attributes for start address of switch 1 are not programmed, use the default: Switch 1 Action
C. If attributes for start address of switch 2 are programmed, get the attribute for switch 2.
D. If attributes for start address of switch 2 are not programmed, use the default: Switch 2 action
A. If the switch 1 is pressed, process it. (see details below)
B. If the switch 2 is pressed, process it. (see details below)
C. If the timer for switch 1 is expired, process it. (see details below)
D. If the timer for switch 2 is expired, process it. (see details below)
E. If the switch 1 is released: Transmit B1H to host if flag is enabled.
F. If the switch 2 is released: Transmit B2H to host if flag is enabled.
G. If there is update flag for switch 1 is set, process it.
address for switch 1 = 0000H, switch 1 action address for switch 2 = 0000H, end address for
switch 1 = 0010H Timer2 for switch 1=00H timer1 for switch 1= 0AH.
address for switch 1 = 0000H, switch 2 action address for switch 2 = 0000H, end address for
switch 2 = 0020H Timer2 for switch 2=00H timer1 for switch 2= 0DH,
Toll Free 1.877.2BUYNKK (877.228.9655) • Phone 480.991.0942 • Fax 480.998.1435
CL01 Intelligent Controller Users Manual
www.nkkswitches.com • Email engineering@nkkswitches.com
Page 7 of 24
0110