MAX11068EVKIT+ Maxim Integrated Products, MAX11068EVKIT+ Datasheet - Page 48

no-image

MAX11068EVKIT+

Manufacturer Part Number
MAX11068EVKIT+
Description
KIT SMART BATT MEASUREMENT 12CH
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of MAX11068EVKIT+

Main Purpose
Power Management, Battery Monitor, Car
Utilized Ic / Part
MAX11068
Primary Attributes
Monitors Current, Voltage, Temperature
Secondary Attributes
1 ~ 12 Cell- Li-Ion, 1 ~ 12 Cell- NiMH
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Embedded
-
12-Channel, High-Voltage Sensor, Smart
Data-Acquisition Interface
Table 24. OVTHCLR—Overvoltage Clear Threshold Register Description (Address 0x18)
Table 25. OVTHRSET—Overvoltage Set Threshold Register Description (Address 0x19)
48
D15
D14
D13
D12
D11
D10
D15
D14
D13
D12
D11
D10
BIT
BIT
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
NAME
NAME
D11
D10
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
0
0
0
0
0
0
0
0
12-bit limit for the reset threshold of overvoltage-alert detection. An alert that is issued when
the overvoltage set threshold is exceeded by a cell voltage is not cleared until the voltage falls
below this lower threshold. The overvoltage alert is updated on each new measurement scan of
the cell voltages by comparing against the threshold values. This alert-clearing threshold builds
in digital hysteresis to the overvoltage detection.
Write ignored; read back 0.
12-bit limit for the triggering threshold of overvoltage-alert detection. An alert for a given cell is
issued when this set threshold is exceeded by the cell voltage and the alert is not cleared until
the cell voltage falls below the clear threshold. The overvoltage alert is updated on each new
measurement scan of the cell voltages by comparing against the overvoltage threshold values.
This alert setting threshold is a critical maximum cell-voltage level.
Write ignored; read back 0.
FUNCTION
FUNCTION