MAX16046 Evaluation Kit
The Data Logging tab (Figure 5) monitors the voltage
at each MON_ input on chart recorder graphs. Each
graph shows the MON_ input being monitored, the
name of any associated power supply, the primary
overvoltage (OV) and undervoltage (UV) thresholds,
and the configurable early warning (EW) threshold. The
dotted lines represent the voltage thresholds, and the
solid green line is the monitored voltage. Items
changed on this tab are immediately written to the reg-
isters of the part.
To modify the primary OV, UV, or EW thresholds for a
particular channel, click the appropriate underlined num-
ber next to that parameter. The thresholds can also be
modified by dragging the dotted lines in the chart
recorder view. The red dotted line represents the primary
OV threshold, the yellow dotted line represents the pri-
mary UV threshold, and the blue dotted line represents
the EW threshold. The Range link provides access to the
input voltage range setting for that channel.
Figure 5. Data Logging Tab
8
_______________________________________________________________________________________
Data Logging Tab
Each channel uses a fault flag indicator to signal if an
undervoltage or overvoltage fault has occurred. The
fault flag indicator turns red and remains so even after
the original fault condition is removed. To clear a fault
indicator, click the indicator and select Clear Fault or
Clear All Faults on the menu that appears. The Fault
Mode link provides access to the fault flag settings for
each channel.
Any modifications to voltage thresholds, range settings,
or fault modes are not propagated back to the Setup
tab, and are lost when the Write To Registers button
on the Setup tab is clicked.
Each chart recorder view shows the current voltage on
the corresponding IN input with a solid green line. To
zoom in and zoom out, click the magnifying glass icons
in the upper left of the chart recorder view. Another way
to zoom in and out is to click and “drag” a selection
rectangle. Drag from upper left to lower right to zoom
in, and drag from the lower right to the upper left to
zoom out.