CDB5351 Cirrus Logic Inc, CDB5351 Datasheet - Page 14

EVALUATION BOARD FOR CS5351

CDB5351

Manufacturer Part Number
CDB5351
Description
EVALUATION BOARD FOR CS5351
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CDB5351

Number Of Adc's
2
Number Of Bits
24
Sampling Rate (per Second)
192k
Data Interface
Serial
Inputs Per Adc
2 Single
Power (typ) @ Conditions
198mW @ 5 V
Voltage Supply Source
Analog and Digital
Operating Temperature
-10°C ~ 70°C
Utilized Ic / Part
CS5351
Product
Audio Modules
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1781
14
2. PIN DESCRIPTIONS
Pin Name
RST
M/S
LRCK
SCLK
MCLK
VD
GND
VL
SDOUT
MDIV
HPF
I²S/LJ
M0
M1
OVFL
AINL
AINR
VQ1
VQ2
VQ3
VA
REF_GND
FILT+
18
10
12
13
14
15
16
21
17
20
22
19
23
24
11
#
1
2
3
4
5
6
7
8
9
Positive Voltage Reference (Output) - Positive reference voltage for the internal sampling circuits.
Pin Description
Reset (Input) - The device enters a low power mode when low.
Master/Slave Mode (Input) - Selects operation as either clock master or slave.
Left Right Clock (Input/Output) - Determines which channel, Left or Right, is currently active on the
serial audio data line.
Serial Clock (Input/Output) - Serial clock for the serial audio interface.
Master Clock (Input) - Clock source for the delta-sigma modulator and digital filters.
Digital Power (Input) - Positive power supply for the digital section.
Ground (Input) - Ground reference. Must be connected to analog ground.
Logic Power (Input) - Positive power for the digital input/output.
Serial Audio Data Output (Output) - Output for two’s complement serial audio data.
MCLK Divider (Input) - Enables a master clock divide by two function.
High Pass Filter Enable (Input) - Enables the Digital High-Pass Filter.
Serial Audio Interface Format Select (Input) -Selects either the Left-Justified or I²S format for the SAI.
Mode Selection (Input) - Determines the operational mode of the device.
Overflow (Output, open drain) - Detects an overflow condition on both left and right channels.
Analog Inputs (Input) - The full-scale analog input level is specified in the Analog Characteristics speci-
fication table.
Quiescent Voltage (Output) - Filter connection for the internal quiescent reference voltage.
Analog Power (Input) - Positive power supply for the analog section.
Reference Ground (Input) - Ground reference for the internal sampling circuits.
SDOUT
MCLK
LRCK
SCLK
I²S/LJ
MDIV
GND
RST
HPF
M/S
VD
VL
1
2
3
4
5
6
7
8
9
10
11
12
24
23
22
21
20
19
18
17
16
15
14
13
FILT+
REFGND
VQ3
AINR
VQ2
VA
GND
VQ1
AINL
OVFL
M1
M0
CS5351
DS565F2

Related parts for CDB5351