EVAL-AD976CB Analog Devices Inc, EVAL-AD976CB Datasheet - Page 6

no-image

EVAL-AD976CB

Manufacturer Part Number
EVAL-AD976CB
Description
BOARD EVAL FOR AD976
Manufacturer
Analog Devices Inc
Datasheet

Specifications of EVAL-AD976CB

Rohs Status
RoHS non-compliant
Number Of Adc's
1
Number Of Bits
16
Sampling Rate (per Second)
100k
Data Interface
Parallel
Inputs Per Adc
1 Single Ended
Input Range
±10 V
Power (typ) @ Conditions
100mW @ 100kSPS
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 85°C
Utilized Ic / Part
AD976
DEFINITION OF SPECIFICATIONS
INTEGRAL NONLINEARITY ERROR (INL)
Linearity error refers to the deviation of each individual code
from a line drawn from “negative full scale” to “positive full
scale.” The point used as negative full scale occurs 1/2 LSB
before the first code transition. Positive full scale is defined as a
level 1 1/2 LSB beyond the last code transition. The deviation is
measured from the middle of each particular code to the true
straight line.
DIFFERENTIAL NONLINEARITY ERROR (DNL)
In an ideal ADC, code transitions are 1 LSB apart. Differential
nonlinearity is the maximum deviation from this ideal value. It
is often specified in terms of resolution for which no missing
codes are guaranteed.
The last + transition (from 011. . .10 to 011. . .11) should
occur for an analog voltage 1 1/2 LSB below the nominal full
scale (9.9995422 V for a 10 V range). The full-scale error is
the deviation of the actual level of the last transition from the
ideal level.
AD976/AD976A
Pin No.
1
2
3
4
5
6
7–13
14
15–21
22
23
24
25
26
27
28
FULL-SCALE ERROR
Mnemonic
V
AGND1
REF
CAP
AGND2
D15 (MSB)
D14–D8
DGND
D7–D1
D0 (LSB)
BYTE
R/C
CS
BUSY
V
V
IN
ANA
DIG
Description
Analog Input. Connect a 200
input range is 10 V.
Analog Ground. Used as the ground reference point for the REF pin.
Reference Input/Output. The internal +2.5 V reference is available at this pin. Alternatively, an
external reference can be used to override the internal reference. In either case, connect a 2.2 F
tantalum capacitor between REF and AGND1.
Reference Buffer Output. Connect a 2.2 F tantalum capacitor between CAP and AGND2.
Analog Ground.
Data Bit 15. Most significant bit of conversion result. High impedance state when CS is HIGH or
when R/C is LOW.
Data Bits 14–8. High impedance state when CS is HIGH or when R/C is LOW.
Digital Ground.
Data Bits 7–1. High impedance state when CS is HIGH or when R/C is LOW.
Data Bit 0. Least significant bit of conversion result. High impedance state when CS is HIGH or
when R/C is LOW.
Byte Select. With BYTE LOW, data will be output as indicated above; Pin 6 (D15) is the MSB,
Pin 22 (D0) is the LSB. With BYTE HIGH, the top and bottom 8 bits of data will be switched;
D15–D8 are output on Pins 15–22 and D7–D0 are output on Pins 6–13.
Read/Convert Input. With CS LOW, a falling edge on R/C puts the internal sample/hold into the
hold state and starts a conversion; a rising edge enables the output data bits.
Chip Select Input. Internally OR’d with R/C. With R/C LOW, a falling edge on CS will initiate a
conversion. With R/C HIGH, a falling edge on CS will enable the output data bits. When CS is
HIGH, the output data bits will be in the Hi-impedance state.
Busy Output. Goes LOW when a conversion is started and remains LOW until the conversion is
completed and the data is latched into the output register. With CS tied LOW and R/C HIGH,
output data will be valid when BUSY rises. The rising edge of BUSY can be used to latch the out-
put data.
Analog Power Supply. Nominally +5 V.
Digital Power Supply. Nominally +5 V.
PIN FUNCTION DESCRIPTIONS
–6–
resistor between V
BIPOLAR ZERO ERROR
Bipolar zero error is the difference between the ideal midscale
input voltage (0 V) and the actual voltage producing the midscale
output code.
INPUT BANDWIDTH
The input bandwidth is that frequency at which the amplitude
of the reconstructed fundamental is reduced by 3 dB for a full-
scale input.
FULL-POWER BANDWIDTH
Full-power bandwidth is defined as the full-scale input fre-
quency at which signal to (Noise + Distortion) degrades to
60 dB, as 10 bits of accuracy.
APERTURE DELAY
Aperture delay is a measure of the Sample-and-Hold Amplifier
(SHA) performance and is measured from the rising edge of the
clock input to when the input signal is held for a conversion.
IN
and the analog signal source. The full-scale
REV. C

Related parts for EVAL-AD976CB