MAX15059EVKIT+ Maxim Integrated Products, MAX15059EVKIT+ Datasheet - Page 10

no-image

MAX15059EVKIT+

Manufacturer Part Number
MAX15059EVKIT+
Description
EVAL KIT FOR MAX15059
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of MAX15059EVKIT+

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
76V, 300mW Boost Converter and Current
Monitor for APD Bias Applications
10
1, 16
PIN
4, 8
10
11
_____________________________________________________________________________________
2
3
5
6
7
9
CLAMP
CNTRL
NAME
MOUT
PGND
SHDN
SGND
RLIM
ILIM
FB
IN
Power Ground. Connect the negative terminals of the input and output capacitors to PGND. Connect
PGND externally to SGND at a single point, typically at the return terminal of the output capacitor.
Input-Supply Voltage. Bypass IN to PGND with a ceramic capacitor of 1FF minimum value.
Active-Low Shutdown Control Input. Apply a logic-low voltage to SHDN to shut down the device.
Connect SHDN to IN for normal operation. Ensure that V SHDN is not greater than the input voltage, V IN .
SHDN is internally pulled low. The converter is disabled when SHDN is left unconnected.
Signal Ground. Connect directly to the local ground plane. Connect SGND to PGND at a single point,
typically near the return terminal of the output capacitor.
Feedback Regulation Input. Connect FB to the center tap of a resistive voltage-divider from the boost
output to SGND to set the output voltage. The FB voltage regulates to 1.23V (typ) when V CNTRL is
above 1.3V (typ) and to V CNTRL when V CNTRL is below 1.2V (typ).
Control Input for Boost Converter Output-Voltage Programmability. CNTRL allows the feedback set-point
voltage to be set externally by CNTRL when V CNTRL is less than 1.2V. Pull CNTRL above 1.3V (typ) to
use the internal 1.23V (typ) feedback set-point voltage.
Open-Drain Current-Limit Indicator. ILIM asserts low when the APD current limit has been exceeded.
Current-Limit Resistor Connection. Connect a resistor from RLIM to SGND to program the APD current-
limit threshold. When RLIM is connected to SGND, the current limit is set to 4.6mA.
Current-Monitor Output. For the MAX15059A, MOUT sources a current equal to I APD . For the
MAX15059B, MOUT sources a current equal to 1/5 of I APD .
Clamp Voltage Input. CLAMP is the external potential used for voltage clamping of MOUT.
TOP VIEW
PGND
BIAS
LX
LX
13
14
15
16
+
12
1
MAX15059
11
2
TQFN
10
3
FUNCTION
EP
9
4
8
7
6
5
SGND
ILIM
CNTRL
FB
Pin Configuration