AS5030 DB austriamicrosystems, AS5030 DB Datasheet - Page 3

BOARD DEMO AS5030

AS5030 DB

Manufacturer Part Number
AS5030 DB
Description
BOARD DEMO AS5030
Manufacturer
austriamicrosystems
Datasheets

Specifications of AS5030 DB

Sensor Type
Magnetic, Rotary Position
Sensing Range
360°
Interface
USB
Voltage - Supply
5V USB or 7.5V
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
AS5030
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Sensitivity
-
AS5030 8 bit high speed magnetic rotary encoder
Demoboard Operation Manual
2.4
After starting the demo software and selecting the “SSI-Readout” tab, the magnet angle, AGC value, PWM out
value are displayed (see Figure 4).
For a correct reading of the magnet angle, the airgap between the AS5030 top side and the magnet should be
chosen that the 0<AGC<63. If the AGC value reaches 63, the ALARM LED will blink to indicate that the magnet is
too far away from the sensor, and the measurement is not accurate or not valid.
Periodic Readout:
State:
Low Power / Ultra Low Power / Wakeup:
Revision 1.0, 29-May-08
SSI-Readout
By unchecking this option, the angle and AGC values are not read anymore, and the displayed value
keep their last state during the normal readout.
The read period can be adjusted between 50ms and 1s (default 200ms), to have more or less reactivity.
Displays the state of the C2 pin on the selected AS5030. By default C2 = 0 (three wires mode).
The Lock indicator is the state of the lock bit in the serial stream. This bit should be always enabled.
Function not yet implemented
www.austriamicrosystems.com
Figure 4: SSI-Readout tab
Page 3 of 8

Related parts for AS5030 DB