STEVAL-MKI090V1 STMicroelectronics, STEVAL-MKI090V1 Datasheet - Page 33

DEMO BOARD FOR LIS331DLF

STEVAL-MKI090V1

Manufacturer Part Number
STEVAL-MKI090V1
Description
DEMO BOARD FOR LIS331DLF
Manufacturer
STMicroelectronics
Series
MEMS, nanor

Specifications of STEVAL-MKI090V1

Sensor Type
Accelerometer, 3 Axis
Sensing Range
±2g, 4g, 8g
Interface
I²C, SPI
Sensitivity
16LSB/g, 8LSB/g, 4LSB/g
Embedded
No
Utilized Ic / Part
LIS331DLF
Acceleration
2 g, 4 g, 8 g
Sensing Axis
Triple Axis
Interface Type
I2C, SPI
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
LIS331DLF
Other names
497-10492

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STEVAL-MKI090V1
Manufacturer:
STMicroelectronics
Quantity:
135
LIS331DLF
7.17
Table 44.
D6 - D0 bits set the minimum duration of the Interrupt 2 event to be recognized. Duration
steps and maximum values depend on the ODR chosen.
INT2_CFG (34h)
Table 45.
Table 46.
Configuration register for Interrupt 2 source.
Table 47.
D6 - D0
AOI
6D
ZHIE
ZLIE
YHIE
YLIE
XHIE
XLIE
AOI
AOI
0
0
INT2_DURATION description
INT2_CFG register
INT2_CFG description
Interrupt mode configuration
AND/OR combination of Interrupt events. Default value: 0.
(See table below)
6 direction detection function enable. Default value: 0.
(See table below)
Enable interrupt generation on Z high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Z low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on Y high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Y low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on X high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on X low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
6D
Duration value. Default value: 000 0000
ZHIE
6D
0
1
Doc ID 15101 Rev 4
ZLIE
YHIE
OR combination of interrupt events
6 direction movement recognition
Interrupt mode
YLIE
Register description
XHIE
XLIE
33/38