STEVAL-MKI091V1 STMicroelectronics, STEVAL-MKI091V1 Datasheet - Page 16

DEMO BOARD FOR LIS331DLM

STEVAL-MKI091V1

Manufacturer Part Number
STEVAL-MKI091V1
Description
DEMO BOARD FOR LIS331DLM
Manufacturer
STMicroelectronics
Series
MEMS, nanor

Specifications of STEVAL-MKI091V1

Sensor Type
Accelerometer, 3 Axis
Sensing Range
±2g, 4g, 8g
Interface
I²C, SPI
Sensitivity
64LSB/G, 32LSB/g, 16LSB/g
Embedded
No
Utilized Ic / Part
LIS331DLM
Acceleration
2 g, 4 g, 8 g
Sensing Axis
Triple Axis
Interface Type
I2C, SPI
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
LIS331DLM
Other names
497-10491
Application hints
4
4.1
16/38
Application hints
Figure 5.
The device core is supplied through Vdd line while the I/O pads are supplied through
Vdd_IO line. Power supply decoupling capacitors (100 nF ceramic, 10 µF Aluminum) should
be placed as near as possible to the pin 14 of the device (common design practice).
All the voltage and ground supplies must be present at the same time to have proper
behavior of the IC (refer to
without blocking the communication bus, in this condition the measurement chain is
powered off.
The functionality of the device and the measured acceleration data is selectable and
accessible through the I
The functions, the threshold and the timing of the two interrupt pins (INT 1 and INT 2) can be
completely programmed by the user through the I
Soldering information
The LGA package is compliant with the ECOPACK
It is qualified for soldering heat resistance according to JEDEC J-STD-020C.
Leave “pin 1 indicator” unconnected during soldering.
Land pattern and soldering recommendations are available at www.st.com.
LIS331DLM electrical connection
Vdd
Digital signal from/to signal controller.Signal’s levels are defined by proper selection of Vdd_IO
100nF
GND
10µF
2
C or SPI interfaces.When using the I
Figure
Vdd_IO
Doc ID 15102 Rev 4
5). It is possible to remove Vdd maintaining Vdd_IO
1
5
5
16
6
TOP VIEW
2
C/SPI interface.
®
, RoHS and “Green” standard.
14
8
13
9
9
2
C, CS must be tied high.
INT 1
INT 2
LIS331DLM

Related parts for STEVAL-MKI091V1