LM95214EB/NOPB National Semiconductor, LM95214EB/NOPB Datasheet - Page 15

no-image

LM95214EB/NOPB

Manufacturer Part Number
LM95214EB/NOPB
Description
BOARD EVALUATION FOR LM95214
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheets

Specifications of LM95214EB/NOPB

Sensor Type
Temperature
Sensing Range
-40°C ~ 140°C
Interface
SMBus (2-Wire/I²C)
Sensitivity
±1°C
Voltage - Supply
3 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
LM95214
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LM95214EB
b) TCRIT2 Mask Register, Status Register 1 and 3, and
a) TCRIT1 Mask Register, Status Register 1 and 2, and
TCRIT1 output logic diagram.
TCRIT2 output logic diagram.
30006151
30006152
15
If enabled, local temperature is compared to the user pro-
grammable Local Tcrit Limit Register (Default Value = 85°C).
The result of this comparison is stored in Status Register 2,
Status Register 3 and Status Register 4 (see Figure 5).The
comparison result can trigger TCRIT1 pin, TCRIT2 pin or
TCRIT3 pin depending on the settings in the TCRIT1 Mask,
TCRIT2 Mask and TCRIT3 Mask Registers (see Figure 6).
The comparison result can also be read back from the Status
Register 2, Status Register 3 and Status Register 4.
If enabled, remote temperature 1 is compared to the user
programmable Remote 1 Tcrit-1 Limit Register (Default Value
110°C) and Remote 1 Tcrit-2 Limit Register (Default Value =
85°C). The result of this comparison is stored in Status Reg-
ister 2, Status Register 3 and Status Register 4 (see Figure
5). The comparison result can trigger TCRIT1 pin, TCRIT2 pin
or TCRIT3 pin depending on the settings in the TCRIT1 Mask,
TCRIT2 Mask and TCRIT3 Mask Registers (see Figure 6).
The comparison result can also be read back from the Status
Register 2, Status Register 3 and Status Register 4. The re-
mote temperature 2 operates in a similar manner to remote
temperature 1 using its associated user programmable limit
registers: Remote 2 Tcrit-1 Limit Register (Default Value 110°
C) and Remote 2 Tcrit-2 Limit Register (Default Value = 85°
C). When enabled, the remote temperature 3 is compared to
the user programmable Remote 3 Tcrit Limit Register (Default
Value 85°C). The comparison result can trigger TCRIT1 pin,
TCRIT2 pin or TCRIT3 pin depending on the settings in the
TCRIT1 Mask, TCRIT2 Mask and TCRIT3 Mask Registers.
The comparison result can also be read back from the Status
Register 2, Status Register 3 and Status Register 4. The re-
mote temperature 4 operates in a similar manner to remote
temperature 3 using its associated user programmable limit
register: Remote 4 Tcrit Limit Register (Default Value 85°C).
FIGURE 6. Logic diagrams for the TCRIT1, TCRIT2, and
c) TCRIT3 Mask Register, Status Register 1 and 4, and
TCRIT3 output logic diagram.
TCRIT3 outputs.
www.national.com
30006153

Related parts for LM95214EB/NOPB