LM95214EB/NOPB National Semiconductor, LM95214EB/NOPB Datasheet - Page 26

no-image

LM95214EB/NOPB

Manufacturer Part Number
LM95214EB/NOPB
Description
BOARD EVALUATION FOR LM95214
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheets

Specifications of LM95214EB/NOPB

Sensor Type
Temperature
Sensing Range
-40°C ~ 140°C
Interface
SMBus (2-Wire/I²C)
Sensitivity
±1°C
Voltage - Supply
3 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
LM95214
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LM95214EB
www.national.com
Register Name
Status 2 (TCRIT1)
2.4.3 Status 2 (TCRIT1)
Status bits for TCRIT1. When one or more of these bits are set and if not masked the TCRIT1 output will activate. TCRIT1 will
deactivate when all these bits are cleared.
Bit(s)
7–5
4
3
2
1
0
Bit Name
-
R4T1
R3T1
R2T1
R1T1
LT1
Read/
Write
RO
RO
RO
RO
RO
RO
Command
Description
Reserved – will report "0" when read.
Remote 4 Tcrit Status:
1 – indicates that remote 4 reading is greater than or equal to the value set in Remote 4
Tcrit Limit register
0 – indicates that that remote 4 reading is less than the value set in Remote 4 Tcrit Limit
register minus the Common Hysteresis value
Remote 3 Tcrit Status:
1 – indicates that remote 3 reading is greater than or equal to the value set in Remote 3
Tcrit Limit register
0 – indicates that that remote 3 reading is less than the value set in Remote 3 Tcrit Limit
register minus the Common Hysteresis value
Remote 2 Tcrit-1 Status:
1 – indicates that remote 2 reading is greater than or equal to the value set in Remote 2
Tcrit-1 Limit register
0 – indicates that that remote 2 reading is less than the value set in Remote 2 Tcrit-1 Limit
register minus the Common Hysteresis value
Remote 1 Tcrit-1 Status:
1 – indicates that remote 1 reading is greater than or equal to the value set in Remote 1
Tcrit-1 Limit register
0 – indicates that that remote 1 reading is less than the value set in Remote 1 Tcrit-1 Limit
register minus the Common Hysteresis value
Local Tcrit Status:
1 – indicates that local reading is greater than or equal to the value set in Local Tcrit Limit
register
0 – indicates that local reading is less than the value set in Local Tcrit Limit register minus
the Common Hysteresis value
(Hex)
Byte
0x08
Read/
Write
RO
D7
26
D6
D5
R4T1 R3T1
D4
D3
R2T1
D2
R1T1
D1
LT1
D0
Default
(Hex)
POR

Related parts for LM95214EB/NOPB