DC-ME-01T-KT Digi International, DC-ME-01T-KT Datasheet - Page 122

KIT INTEGRATION ME MOD S MODELS

DC-ME-01T-KT

Manufacturer Part Number
DC-ME-01T-KT
Description
KIT INTEGRATION ME MOD S MODELS
Manufacturer
Digi International
Series
Digi Connect ME®r
Type
MCU Moduler
Datasheets

Specifications of DC-ME-01T-KT

Contents
Module with plug-and-play firmware, Development Board, Documentation, CD, Cables and Power Supply
Silicon Manufacturer
Digi Intl
Kit Application Type
Communication & Networking
Application Sub Type
Embedded
Silicon Family Name
Digi Connect ME
Rohs Compliant
Yes
For Use With/related Products
Digi Connect ME S Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
602-1057
Restore Device Configuration to Factory Defaults
1 2 2
A d m i n i s t r a t i o n f r o m t h e D e f a u l t W e b I n t e r f a c e
Before uploading the firmware or the boot/POST code, it is very important to read the
Release Notes that are supplied with the firmware to check if the boot/POST code must be
updated before updating the firmware.
Prerequisites
These procedure assume that:
Update Firmware from a File on Your PC
1
2
3
4
5
6
Update Firmware from a TFTP Server
Updating firmware from a TFTP server is done from the Command-Line Interface using
the boot command. It cannot be done from the default web interface. For details, see
"Administration from the Command-Line Interface" on page 129.
There are two ways to restore the device configuration to the factory default settings:
You have already downloaded the firmware file from the Digi web site.
If you are using the TFTP option, that TFTP is running.
Open a web browser and enter the device server’s IP address in the URL window.
If security is enabled for the device, a login prompt is displayed. Enter the user
name and password for the device. If you do not know the user name and password,
contact the system administrator who initially set up the device.
Click Upgrade Firmware from the main menu.
Select Firmware.
Click Browse to select the file.
Click Update.
Important: DO NOT close your browser until the update is complete and you have
been prompted to reboot.
Restore the configuration from a web browser which will clear all current
settings except the IP address settings and administrator password. This is the
best way to reset the configuration because you can also back up the settings
(which provides a means for restoring it after you have worked through
D i g i C o n n e c t F a m i l y U s e r ’ s G u i d e

Related parts for DC-ME-01T-KT