101-1069 Rabbit Semiconductor, 101-1069 Datasheet - Page 51

KIT DEVELOPMENT RCM3305 US

101-1069

Manufacturer Part Number
101-1069
Description
KIT DEVELOPMENT RCM3305 US
Manufacturer
Rabbit Semiconductor
Series
RabbitCore 3000r
Type
MPU Moduler
Datasheet

Specifications of 101-1069

Contents
RabbitCore Module, Dev. Board, AC Adapter, Cable and Dynamic C® CD-Rom
Processor To Be Evaluated
RCM3305
Interface Type
Ethernet
For Use With/related Products
RCM3305
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
316-1129
PARAMETERS
RETURN VALUE
SEE ALSO
5.2.6.4 Serial Communication
SEE ALSO
SEE ALSO
User’s Manual
void relayOut(int relay, int value);
void ser485Tx(void);
void ser485Rx(void);
Sets the position for the relay common contact. The default position is for normally closed contacts.
relay is the one relay (1)
value is the value used to connect the relay common contact:
None.
Enables the RS-485 transmitter. Transmitted data are echoed back into the receive data buffer. The
echoed data may be used as an indicator for disabling the transmitter by using one of the following meth-
ods:
Remember to call the serXopen() function before running this function.
Disables the RS-485 transmitter. This puts the device into the listen mode, which allows it to receive data
from the RS-485 interface.
Remember to call the serXopen() function before running this function.
Byte mode—disable the transmitter after the same byte that is transmitted is detected in the receive
Block data mode—disable the transmitter after the same number of bytes transmitted are detected in
brdInit
ser485Rx
ser485Tx
0 = normally closed positions (NC1 and NC2)
1 = normally open positions (NO1 and NO2)
data buffer.
the receive data buffer.
45