DEMO908GZ60E Freescale Semiconductor, DEMO908GZ60E Datasheet - Page 6

BOARD DEMO FOR 908GZ60 MCU

DEMO908GZ60E

Manufacturer Part Number
DEMO908GZ60E
Description
BOARD DEMO FOR 908GZ60 MCU
Manufacturer
Freescale Semiconductor
Series
HC08GRr
Type
MCUr
Datasheets

Specifications of DEMO908GZ60E

Design Resources
DEMO908GZ60E Schematic
Contents
Board, Cable, CD
Processor To Be Evaluated
908GZ
Data Bus Width
16 bit
Interface Type
RS-232
For Use With/related Products
68HC908GZ60
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
D E M O 9 0 8 R G 6 0
Reference Documentation
Reference documents are provided on the support CD in Acrobat Reader format.
DEMO908GZ60_SCH_C.pdf
DEMO908GZ60_UG.pdf
MC68HC908GZ60/D.pdf
See the HC08 Support CD provided with this board for all the documentation and support files
provided.
GETTING STARTED
The DEMO908GZ60 Module operates in two basic Modes, Run Mode, or MON08 Debug
Mode. Run Mode supports user application operation from Power On or Reset condition.
MON08 Debug Mode supports the development and debug of applications via the MON08
embedded debug monitor. See the related sections below for quickly starting the module in
the desired operation mode.
The Module may be operating a Demonstration (DEMO) program when shipped from the
factory. If so, the Module kit contents will include a Quick Start document explaining the
operation of the Demonstration program. The demo program operates in RUN Mode.
The module must be powered to operate. The +5V will light when the board is powered from
the on-board regulator, or if the board is setup to provide power to an external circuit through
connector J1. The +5V LED should not light when the board is powered through connector J1.
If it does, the PWR_SEL jumper is incorrectly configured and may result in damage to the on-
board regulator. Refer to the PWR_SEL option and J1 connector chapter for more detail on
these selections.
RUN MODE
RUN Mode operates the HC08 application contained in the internal flash memory from Reset
or Power On condition. Use the following settings to configure the DEMO908GZ60 module for
RUN Mode to get started quickly.
1. Configure PWR_SEL option for input supply to power the module. If supply is via J1 con-
2. Connect serial communication cable between the module COM port and the host if needed.
nection, install module on J1 external connection in powered down condition.
Launch supporting host software for the module communication.
DEMO908GZ60 Module Schematic Rev. C
DEMO908GZ60 User Guide (this document)
68HC908GZ60 Device User Guide
6
A U G U S T
6 ,
2 0 0 4

Related parts for DEMO908GZ60E