R0K42215RS001BE Renesas Electronics America, R0K42215RS001BE Datasheet - Page 2

KIT STARTER FOR H8S/2215R

R0K42215RS001BE

Manufacturer Part Number
R0K42215RS001BE
Description
KIT STARTER FOR H8S/2215R
Manufacturer
Renesas Electronics America
Series
H8®r
Type
MCUr

Specifications of R0K42215RS001BE

Contents
Evaluation Board
For Use With/related Products
H8S/2215
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2. Connection
11. Ensure that “E10A enable” jumper (J13) is fitted.
12. Connect the E10A module to the ‘E10A’ connector on the RSK using the ribbon cable.
13. Plug in the LCD module to ‘LCD’ connector on the RSK ensuring that the pin 1 designation corresponds to the marking on the RSK.
14. Connect the 5V power supply unit to the power jack on the RSK board and apply power. The green ‘Power’ LED located on the RSK will illuminate.
15. Connect the E10A module to a spare USB port on your PC. The green ‘ACT’ LED on the RSK will illuminate.
16. Verify the “Recommended” option (Renesas E-Series USB Driver) is selected and click <Next>.
17. If using Windows XP, skip to step 19; otherwise click <Next>.
18. Click <Next> to install the driver.
19. Click <Finish> to close the wizard.
Note: The Windows driver signing dialog may be displayed. Please accept the driver to continue.
3. HEW Workspace
HEW integrates various tools such as compiler, assembler, debugger and editor into a common graphical user interface. To learn more on how to use HEW, open the
HEW manual installed on your computer (Start Menu > All Programs > Renesas > High-performance Embedded Workshop > Manual Navigator).
20. Launch HEW from the Start Menu (Start Menu > All Programs > Renesas > High-performance Embedded Workshop).
21. In the “Welcome” dialog box: Verify “Create New Workspace” is selected. Click <OK>
22. In the “New Project Workspace” dialog box: Verify the “CPU Family” is set “H8S,H8/300”. Select “E10A_RSKH8S2215R” from the left hand pane.
23. Enter a name for the workspace. The project name will be automatically completed with the Workspace name. You can change this name to ‘Tutorial’ if required.
24. On the “E10A_RSKH8S2215R – Step 1” window: Select “Tutorial” and click <Next>.
25. On the “E10A_RSKH8S2215R – Step 2” window: Click <Finish>.
26. On the Project Generator Information window: Click <OK>.
27. Select the ‘Debug’ build configuration in the left hand drop down list on the tool bar.
28. Click on the ‘Build’ icon to compile, assemble and link the project.
4. Programming and Debug
29. Select the “SessionH8S_2215RF_E10A_USB_SYSTEM” session in the right hand drop
30. Click the <Connect> button on the debug toolbar.
31. The ‘Select Emulator mode’ dialog will appear. Select the
First use of the E10A module
32. The ‘ Please choose driver’ dialog will be shown. Click <OK>
33. The ‘Driver Details’ dialog will be shown, please select “Renesas E-Series USB Driver” as illustrated. The
34. The Firmware setup dialog will be shown warning you not to disconnect the USB cable until the firmware download
35. The firmware will be downloaded to the E10A module; this will take a few moments.
The ‘Found New Hardware’ Wizard will appear. Please follow the steps below to install the drivers. Note that administrator privileges are required for a Windows™
2000/XP machine. If offered, do not use the Windows Update option to locate the driver.
Click <OK>.
The project that is created has two configurations. The Release configuration compiles the project without any debugger support and can be used for the final
release code version.
down list on the tool bar. The Debug toolbar connection button should be active.
device “H8S/2215RF” and the “E10A-USB Emulator” radio
button and click <OK>.
If this isn’t the first time you have used the E10A module with this RSK, please skip to step 36.
‘Interface’ and ‘Channel’ items will be automatically populated. Click <Close>.
is complete. Click <OK>.
Please do not disconnect the E10A from the host during download, doing so is likely to damage the E10A
module.