DemoKit-KA1 User’s Manual
6.3.2.4 Verify Command
This command is not supported.
6.3.2.5 Security Command
This command is not supported.
6.3.2.6 Checksum Command
The Checksum command reads the checksum value of the 78K0S/KA1+ device connected with
the PG-LPC. This value differs from the value displayed in the parameter window of the main
window.
6.3.2.7 Autoprocedure (EPV) Command
The Autoprocedure(EPV) command executes the Erase and Program commands in
succession. Upon completion of Autoprocedure(EPV) command execution, the GUI software
displays the result of executing the command on the target device.
6.3.2.8 Signature Read Command
This command is not supported.
6.3.2.9 Setup Command
The Setup command allows you to make settings related to flash memory rewriting according
to the user environment and to set command options. Each time the GUI software is started, the
most recently used parameter file (.PRM) is read and the settings are displayed. The Device
Setup dialog box allows you to modify the settings of items other than those consisting of
shadowed characters according to the user environment. The Standard tab is used to set the
environment for rewriting the flash memory of the target device. The mode of communication
with the target, the operating clock, and so forth differ depending on the device used.
Figure 37. Device Setup Window: Standard