Table 5.2 Error display and how to remedy it when starting up the emulator (2/2)
(2) Troubleshooting When Emulator Debugger M3T-PD308M Starts Up
Table 5.3 lists error messages and how to remedy them when starting up M3T-PD308M.
Table 5.3 Error message and how to remedy it when starting up M3T-PD308M
Communication ERROR.
Can't accept data.
Not Compact Emulator.
Target MCU is not given clock.
Target MCU is unable to reset.
The version of M3T-PD308M and
the firmware on the target are not
same.
Please download the firmware
to target.
POWER CLOCK
POWER CLOCK
POWER CLOCK
POWER CLOCK
POWER CLOCK
LED display
Error message
: Blinking
: OFF
RESET
RESET
RESET
RESET
RESET
RUN
RUN
RUN
RUN
RUN
Connection to the
target system
-
Connection to the
( 42 / 52 )
Not connected
Not connected
target system
Connected
Connected
-
-
-
-
Emulator does not work properly.
- The emulator may be damaged. Report the state of
target status LEDs to your local distributor.
- Check the emulator's target status LEDs. If
flashing, the emulator is not working properly.
Check the settings as explained in "(1)
Troubleshooting When the Emulator Starts
Up".
- Check the connected serial port and the serial
port settings in the Init dialog box match.
- Try lowering the baud rate in the Init dialog
box.
- Check the connected serial port and the serial
port settings in the Init dialog box match.
- Check an emulator (such as PC4701M,
PC4701HS or PC4701L) is not connected.
- If the Clock tab in the Init dialog box is set to
"External", check the target system's oscillation
circuit works properly.
- If the Clock tab in the Init dialog box is set to
"External", change it to "Internal".
- If the Clock tab in the Init dialog box is set to
"External", check the target system's oscillation
circuit works properly.
- If the Clock tab in the Init dialog box is set to
"External", change it to "Internal".
- Contact your local distributor.
- Contact your local distributor.
Checkpoint
Checkpoint