Renesas Electronics America
Series
SuperH®r
Type
In-Circuit Emulatorr
Datasheet

Specifications of R0E0200F0EMU00

Contents
Emulator Board, Cables, Software and Documentation
For Use With/related Products
SH7780
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
5.9.12
1. Tolerances
2. Functions that cannot be used while the profiling function is being used
266
The profiling function internally breaks user program execution, collects the measured data,
and re-executes the user program.
Since the function also counts when the measured item is generated at break or re-execution,
tolerances will be included in the measured profile value.
The measured value of this function should be the reference.
(a) On-chip performance analysis function
(b) Step function
(c) Internal trace function
(d) Halt function
(e) Memory access during user program execution
(f) When the profiling function is used, a break occurs if a branch instruction is generated.
(g) When the profiling function is used, do not use the function of Break Condition 3.
(h) When the profiling function is used, do not set [Hardware break enable] for [Emulation
(i) When the profiling function is used, the PC and SR values are displayed as undefined on
The on-chip performance analysis function cannot be used when the profiling function is
enabled.
When the profiling function is enabled, do not use the step function. The profile data
cannot be measured correctly.
When the profiling function is enabled, it is invalid to select the internal trace mode as all
items of the internal trace mode are internally selected. Do not use the internal trace when
the profiling function is enabled.
When the profiling function is enabled, do not use the halt function of the internal, AUD,
external bus, and MFI traces.
When the profiling function is enabled, memory access is disabled during user program
execution.
Accordingly, the realtime emulation will not be performed. In addition, since the emulator
firmware is controlled on generation of a break, the executed result of the branch
instruction may be displayed on the [Internal/AUD/Usermemory trace] window when the
execution is returned to the user program from the emulator firmware. In this case,
**EML** is displayed.
mode] in the [Configuration] dialog box.
the status bar.