HS3664EPI62H Renesas Electronics America, HS3664EPI62H Datasheet - Page 224

no-image

HS3664EPI62H

Manufacturer Part Number
HS3664EPI62H
Description
EMULATOR BASE UNIT H8/3664
Manufacturer
Renesas Electronics America
Type
In Circuit Debuggerr
Datasheet

Specifications of HS3664EPI62H

Contents
E6000 Emulator and CD-ROM
For Use With/related Products
H8/3664
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
8.2 Notes on Usage of the H8/3664 E6000 Emulator
There are the following notes on usage of the emulator.
8.2.1
In the E6000 emulator, one evaluation chip emulates several types of MCU. Therefore, there are some
differences in I/O registers between an actual MCU and the emulator. Note these differences when accessing the
I/O registers.
I/O port is in the input state at default. The I/O register contents indicate the emulator port status. When the user
system interface cable is not connected, the read value is 1 due to pull-up resistors.
In the emulator, accesses to the following registers for controlling the flash memory are invalid.
• Flash memory control register 1 (FLMCR1: H'FF90)
• Flash memory control register 2 (FLMCR2: H'FF91)
• Flash memory power control register (FLPWCR: H'FF92)
• Block register 1 (EBR1: H'FF93)
• Flash memory enable register (FENR: H'FF9B)
Note: The addresses indicate the lower 16 bits.
(1) Warnings that Apply to H8/3664 Group Programming
Table 8.14 Differences between the H8/3664 Group Products (1)
Target Address
H’FFE0
Table 8.15 Differences between the H8/3664 Group Products (2)
Target Address
H’FFE1
H’FFF9
Table 8.16 Differences between the H8/3664 Group Products (3)
Target Address
H’FFE2
H’FFF5
H’FFFA
H’FFFB
202
(a) The description given in the hardware manual is “Initial value: 1. Reserved. These bits are always read as
(b) The description given in the hardware manual is “Initial value: 0. Reserved. These bits are always read as
(c) The description given in the hardware manual is “Reserved”. However, the description in the emulator
0”. However, the description in the emulator manual is “Always specify 0. These bits are always read as
the specified values”.
manual is “Always specify 0. These bits are always read as the specified values”.
1”. However, the description in the emulator manual is “Always specify 0. These bits are always read as
the specified values”.
I/O Register
Register Name
Port mode register 1
Register Name
Port mode register 5
Module standby control register 1
Register Name
Port mode register 3
Interrupt enable register 2
Module standby control register 2
Module standby control register 3
Bits
3 and 2
Bits
7 and 6
7
Bits
7 to 3
7 to 5
7 to 0
0