DAK-34 Power Integrations, DAK-34 Datasheet - Page 11

KIT DESIGN ACCELERATOR AC/DC PS

DAK-34

Manufacturer Part Number
DAK-34
Description
KIT DESIGN ACCELERATOR AC/DC PS
Manufacturer
Power Integrations
Series
TOPSwitch®-GXr
Datasheets

Specifications of DAK-34

Main Purpose
AC/DC, Primary Side
Outputs And Type
1, Isolated
Power - Output
30W
Voltage - Output
12V
Current - Output
2.5A
Voltage - Input
85 ~ 265VAC
Regulator Topology
Flyback
Frequency - Switching
132kHz
Board Type
Bare (Unpopulated) and Fully Populated
Utilized Ic / Part
TOP245
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
596-1004
7
7.1
7.2
7.3
Page 11 of 28
Electrical Strength
Primary Inductance
Resonant Frequency
Primary Leakage Inductance
Item
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Transformer Specification
Electrical Diagram
Electrical Specifications
Materials
Core: EF25 Nippon Ceramic NC-2H material or equivalent. Gapped for AL of 246 nH/T
Bobbin: 10 pin EF25, Vertical Mount, Miles-Platts FE0100 with TBS-601 pins or equivalent
Magnet Wire: #26 AWG Double Coated
Triple Insulated Wire: #25 AWG
Tape, 3M #44 or equivalent 1.5 mm wide (min.)
Tape, 3M #1298 or equivalent 14.2 mm wide
Tape, 3M #1298 or equivalent 15.7 mm wide
Varnish
2 x #26 AWG
WDG #2 5T
WDG #1 58T
Figure 4 – EP-34 Triple Insulated Transformer.
#26 AWG
1
3
5
4
1 second, 60 Hz, from Pins 1-5 to Pins 6-10
Pins 1-3, all other windings open, measured at
100 kHz, 0.4 VRMS
Pins 1-3, all other windings open
Pins 1-3, with Pins 6-10 shorted, measured at
100 kHz, 0.4 VRMS
Description
Tel: +1 408 414 9200 Fax: +1 408 414 9201
Triple Insulated
4 x #25 AWG
WDG #3 6T
9, 10
6, 7
Power Integrations
www.powerint.com
750 kHz (Min.)
827 µ H, ± 10%
20 µ H (Max.)
3000 VAC
2

Related parts for DAK-34