AD9380
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
V
V
DV
PV
Analog Inputs
Digital Inputs
Digital Output Current
Operating Temperature Range
Storage Temperature Range
Maximum Junction Temperature
Maximum Case Temperature
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
D
DD
DD
DD
Rating
3.6 V
3.6 V
1.98 V
1.98 V
20 mA
−25°C to +85°C
V
5 V to 0.0 V
−65°C to +150°C
150°C
150°C
D
to 0.0 V
Rev. 0 | Page 6 of 60
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
EXPLANATION OF TEST LEVELS
Table 4.
Level
I
II
III
IV
V
VI
Test
100% production tested.
100% production tested at 25°C and sample tested at
specified temperatures.
Sample tested only.
Parameter is guaranteed by design and
characterization testing.
Parameter is a typical value only.
100% production tested at 25°C; guaranteed by
design and characterization testing.

Related parts for AD9380/PCB