KP125 EVAL BOARD Infineon Technologies, KP125 EVAL BOARD Datasheet - Page 16
KP125 EVAL BOARD
Manufacturer Part Number
KP125 EVAL BOARD
Description
BOARD EVALUATION KP125
Manufacturer
Infineon Technologies
Type
Pressure Sensorr
Specifications of KP125 EVAL BOARD
Contents
Fully Assembled Evaluation Board
For Use With/related Products
KP125
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
KP125EVALBOARDIN
6.2
Overall accuracy covers the entire pressure and temperature range from all sources of error including the
following:
•
•
•
Note: Ratiometric signal error is not included in the overall accuracy. For error measurements, the supply voltage
The error band is determined by three continuous lines through four relevant break points:
Table 7
Temperature Point (°C)
– 40
0
85
125
Figure 9
Data Sheet
Pressure:
Output deviation from target transfer function over the specified pressure range.
Temperature:
Output deviation over the temperature range.
Aging
All drifting parameters during operating time.
must have the nominal value ( V
Overall Accuracy
Accuracy
Overall Error Over Temperature
2.5
2.0
1.5
1.0
0.5
0.0
-40
DD
Error (kPa)
± 2.4
± 1.2
± 1.2
± 2.4
= V
DD
,
0
TYP
).
16
T (°C)
Error Multiplier
2
1
1
2
85
Rev 2.14, 2007-11-23
Pressure Sensor
125
Accuracy
KP125