G2R-1-S AC240(S) Omron, G2R-1-S AC240(S) Datasheet - Page 3

RELAY GP SPDT 240VAC PLUG-IN

G2R-1-S AC240(S)

Manufacturer Part Number
G2R-1-S AC240(S)
Description
RELAY GP SPDT 240VAC PLUG-IN
Manufacturer
Omron
Series
G2RSr
Datasheets

Specifications of G2R-1-S AC240(S)

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
10A
Switching Voltage
440VAC, 125VDC - Max
Coil Type
Standard
Coil Current
3.2mA
Coil Voltage
240VAC
Turn On Voltage (max)
192 VAC
Turn Off Voltage (min)
72 VAC
Mounting Type
Socket
Termination Style
Quick Connect - .187" (4.7mm)
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
10A @ 250VAC
Control On Voltage (max)
192 VAC
Control Off Voltage (min)
72 VAC
Contact Rating
10 A
Contact Termination
Pin
Mounting Style
Plug-In
Power Consumption
0.9 VA
Contact Material
Silver Alloy
Coil Resistance
30.36 K Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2R-1-S-AC240(S)
G2R-1S-AC240(S)
G2R1SAC240S
Z2227
Operation
■ Single-side Stable Relays
The contacts of this simple type of relay momentarily turn ON and
OFF, depending on the energized state of the coil.
■ Dual Coil, Latching Relays
This latching relay has two coils: set and reset. It can retain the ON
or OFF states even when a pulsating voltage is supplied, or when the
voltage is removed.
Contact Styles
Contact ratings are generally indicated according to resistive loads
and inductive loads (cosφ = 0.4 or L/R = 7 ms). Contact shape and
material are also shown to guide the customer in selection of a
model suitable for the intended load and required service life.
(Standard/Non-latching)
Mounting orientation mark
Mounting orientation mark
Terminal Arrangement/
Internal Connections
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
S: Set coil
R: Reset coil
Example
S R
0.001
0.01
0.1
1
Gold-clad
bifurcated
crossbar
contact
Electromechanical Relays
Gold-plated
single contact
■ Single Coil, Latching Relays
Unlike the dual coil latching relay, the single-winding latching relay
has only one coil. This coil, however, serves as both the set and reset
coils, depending on the polarity (direction) of current flow. When cur-
rent flows through the coil in the forward direction, it functions as a
set coil; when current flows through the coil in the reverse direction, it
functions as a reset coil.
■ Built-in Diode
A diode is built into some relays, wired in parallel with the coil to
absorb the counterelectromotive force (counter emf) generated by
the coil.
■ Built-in Operation Indicator
Some relays are provided with a light-emitting diode (LED), wired in
parallel with the coil. This permits a fast-check of the relay’s operat-
ing status.
When used at extremely low loads, the failure rate differs according
to the contact material and contact method, as shown in the figure.
For example, in comparing a single contact point with a bifurcated
contact point, the bifurcated contact model has higher parallel redun-
dancy and will therefore exhibit a lower failure rate.
Gold-plated
bifurcated
contact
10 VDC (constant)
Mounting orientation mark
Technical Information
Load current (mA)
Terminal Arrangement/
Internal Connections
(Bottom View)
S: Set coil
R: Reset coil
S R
3