G7SA-3A1B-DC24 Omron, G7SA-3A1B-DC24 Datasheet - Page 5

RELAY SAFETY PCB 3PST-NO/1NC 24V

G7SA-3A1B-DC24

Manufacturer Part Number
G7SA-3A1B-DC24
Description
RELAY SAFETY PCB 3PST-NO/1NC 24V
Manufacturer
Omron
Series
G7SAr
Datasheets

Specifications of G7SA-3A1B-DC24

Relay Type
Safety
Contact Form
4PST (3 Form A, 1 Form B)
Contact Rating (current)
6A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Standard
Coil Current
20.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Socket
Termination Style
Socketable
Circuit
4PST (3 Form A, 1 Form B)
Contact Rating @ Voltage
6A @ 30VDC
Control On Voltage (max)
18 VDC
Control Off Voltage (min)
2.4 VDC
Contact Rating
6 A
Contact Termination
Pin
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G7SA3A1BDC24
Z2943
Certified Standards
G7SA
Back-mounting Socket (for PCB)
P7SA-10P
Back-mounting Socket (for PCB)
P7SA-14P
• EN Standards, VDE Certified
• UL standard UL508 Industrial Control Devices
• CSA standard CSA C22.2 No. 14 Industrial Control Devices
EN61810-1 (Electromechanical non-specified time all-or-nothing
relays)
EN50205 (Relays with forcibly guided (linked) contacts)
0.5
(11.1)
4.1
24.8
60 max.
0.5
(11.1)
49.9
4.1
0.4
24.8
50 max.
(11.1)
39.9
15 max.
Three, 2.6 dia.
(for M3 tapping screws)
0.5
41.5 max.
3.5
0.4
(11.1)
15 max.
Three, 2.6 dia.
(for M3 tapping screws)
0.5
41.5 max.
3.5
G7SA-5A1B Mounted
G7SA-4A2B Mounted
G7SA-3A3B Mounted
Terminal Arrangement/Internal
Connection Diagram
(Bottom View)
0
1
0
1
0
1
Terminal Arrangement/Internal
Connection Diagram
(Bottom View)
11
23
21
21
11
11
12
G7SA-3A1B Mounted
24
12
22
12
22
G7SA-2A2B Mounted
0
1
0
1
33
43
33
43
31
43
34
44
34
44
32
44
Forcibly Guided Contacts
If an NO contact becomes welded, all NC contacts will maintain a
minimum distance of 0.5 mm when the coil is not energized. Likewise
if an NC contact becomes welded, all NO contacts will maintain a
minimum distance of 0.5 mm when the coil is energized.
11
23
21
11
53
63
53
63
53
63
12
24
12
22
54
54
54
64
64
64
33
43
33
43
34
44
34
44
Note: Terminals 23-24, 33-34, 43-44,
Mounting Hole Placement
(Bottom View)
(±0.1 tolerance)
Mounting Hole Placement
(Bottom View)
(±0.1 tolerance)
53-54, and 63-64 are normally
open. Terminals 11-12, 21-22,
and 31-32 are normally closed.
Note: Terminals 23-24, 33-34, and 43-44
are normally open. Terminals 11-12
and 21-22 are normally closed.
Fourteen,
1.1 dia.
Three, 3.2 dia.
(for M3 tapping
screws)
Ten, 1.1 dia.
Three, 3.2 dia.
(for M3 tapping screws)
(from EN50205)
G7SA
5