P2CF-08-E Omron, P2CF-08-E Datasheet - Page 3

SOCKET 8-PIN FOR H3CR-H

P2CF-08-E

Manufacturer Part Number
P2CF-08-E
Description
SOCKET 8-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr

Specifications of P2CF-08-E

Number Of Positions
8
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Size
70 mm x 50 mm x 19 mm
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
8
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
Number Of Poles
8
Mounting Style
DIN Rail
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2382 - RELAY REPEAT CYCLE ANLG 30HRS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF-08-E
P2CF08E
Z2836

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P2CF-08-E
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
■ Connections
Connecting the Input
• Connect a thermocouple, the E52-THE@ Thermistor (replaceable
• On the E52-@@1D, the lead wires are thermocouple element wires,
Nomenclature
element) or a platinum resistance thermometer to terminals 1
(positive) and 2 (negative) on the E5C2 as shown in the following
illustration.
making them difficult to solder because solder will not stick to them
easily. Remove the crimp terminal and polish the ends before
attempting to solder them.
Thermocouple input
Thermistor with
replaceable element
Temperature setting knob
Platinum resistance
thermometer input
RESET adjustment shaft
No reset function is incorporated by any
E5C2 model with ON/OFF control.
Power supply
100/110/120 VAC (same model) or
200/220/240 VAC (same model)
50/60 Hz
Operation indicator
Output
• If the load circuit is a heating control system, be sure to connect the
• We recommend using an external relay to extend the electrical life
Power Supply
• If a single power supply is used for the E5C2 and the load, the
• The E5C2 operates at either 50 or 60 Hz.
• Different models must be order for 100 to 120 VAC and 200 to
Operation Indicator
Red Lit
load to terminals 4 and 5. If the load circuit is a cooling control
system, be sure to connect the load to terminals 4 and 6.
of internal relays when driving a large capacity load. This is
particularly important when the output relay is switched frequently
(e.g., with proportional control).
supply voltage of the power supply may vary greatly when the load
is open or closed if the capacity of the power supply is not large
enough. Make sure that the capacity of the power supply is large
enough so that the supply voltage range will be always from 90% to
110% of the rated supply voltage.
240 VAC.
Indicator
Not lit
NO contacts (4 and 5) NC contacts (4 to 6)
ON
OFF
Output
OFF
ON
E5C2
3