27E194 Tyco Electronics, 27E194 Datasheet - Page 4

SOCKET 4POLE R10 SERIES

27E194

Manufacturer Part Number
27E194
Description
SOCKET 4POLE R10 SERIES
Manufacturer
Tyco Electronics
Series
R10r
Type
Socketr
Datasheets

Specifications of 27E194

Number Of Positions
16
Mounting Type
Through Hole
Termination Style
PC Pin
Features
Grounding Terminal
Accessory Type
Socket
Associated Relay Series
R10
Number Of Poles
4
For Use With/related Products
R10 Series
For Use With
R10-E1Y4-JJ1.0K - RELAY GP 4PDT 3AR10-E1X4-V52 - RELAY DRY CIR 5A PCBR10-E1M4-V2.5K - RELAY DRY CIR 5AR10-E1L4-115V - RELAY DRY CIR 7.5AR10-E1W4-115V - RELAY GP DPDT 7.5A 115VACR10-E1P4-V15.0K - RELAY GP 4PDT 3A 115VDCR10-E1P4-V185 - RELAY GP 4PDT 3A 12VDCR10-E1P4-V700 - RELAY GP 4PDT 3A 24VDCR10-E1P4-115V - RELAY GP 4PDT 3A 115VACR10-E1W4-S1.8K - RELAY GP 4PDT 7.5A 24VDCR10-E1W4-V185 - RELAY GP 4PDT 7.5A 12VDCR10-E1Y4-JJ2.5K - RELAY GP 4PDT 3AR10-E1Y4-J1.0K - RELAY GP 4PDT 3AR10-E1Y4-J2.5K - RELAY GP 4PDT 3AR10-E1W4-V2.5K - RELAY GP 4PDT 7.5A 48VDCR10-E1X4-24V - RELAY GP 4PDT 5A 24VACR10-E1X4-S450 - RELAY GP 4PDT 5A 12VDCR10-E1X4-V15.0K - RELAY GP 4PDT 5A 115VDCR10-E1Z4-115V - RELAY GP 4PDT 2A 115VACR10-E1Z4-J1.0K - RELAY GP 4PDT 2AR10S-E1Y4-J1.0K - RELAY GP 4PDT 3A 40MWR10-E1Z4-V700 - RELAY GP 4PDT 2A 24VDCR10-E1Z4-V185 - RELAY GP 4PDT 2A 12VDCR10-E1Z4-V2.5K - RELAY GP 4PDT 2A 48VDCPB772 - RELAY GP 4P 7.5A 24VDC CVR SLDPB599 - RELAY GP 4PDT 5A 115VAC PNL MNTPB453 - RELAY GP 5A 4PDT 24VDCR10E1Y4J10.0KBULK - GENERAL PURPOSE RELAYPB131 - RELAY GP 5A 4PDT 48VDCPB130 - RELAY GP 5A 4PDT 24VDCPB129 - RELAY GP 5A 4PDT 12VDCPB123 - RELAY GP 3A 4PDT 48VDCPB122 - RELAY GP 3A 4PDT 24VDCPB121 - RELAY GP 3A 4PDT 12VDCPB120 - RELAY GP 3A 4PDT 6VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2-1393143-2
PB804
4
4
NIB .091 DIA. x .020 HIGH
10
09-2010, Rev. 0910
09-2010, Rev. 0910
www.te.com
www.te.com
© 2010 Tyco Electronics Ltd.
© 2010 Tyco Electronics Ltd.
Terminal assignment
Insulation Data
Initial dielectric strength
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
Ambient temperature
Category of environmental protection
Dimensions
Terminal dimensions
Solder terminal dimensions
8
Initial insulation resistance
4
1 POLE
between open contacts
between contact and coil
between adjacent contacts
between insulated elements
IEC 61810
(2.03)
.080
3
6
(2.31)
9
(2.29)
.090
2
3-48 THREAD
7
5
1
(.51)
(10.31)
.406
10
8
4
(.30)
.012
(1.02)
2 POLE
.735 MAX.
.040
3
(18.67)
}
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
6
9
TYPE E1 ONLY
2
7
5
1
(8.99)
.354
(3.43)
.135
.085 MAX.
13
RTI - dust protected and RTIII - wash tight
16
14
11
CASE E
(2.16)
.59 REF.
ONLY
(15.0)
4
(4.43)
(5.33)
.210
3 POLE
.171
General Purpose Relays
General Purpose Relays
Industrial Relays
Industrial Relays
R10 Series Panel Plug-in Relay
15
12
3
9
6
Datasheets and product specification ac-
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
together with the ‘Definitions’ section.
2
10
STUD ON NARR OW
8
7
5
1
THREAD
R10S: 1.50 MAX.
(24.13, 2 POLE 1R10)
(29.59, 4 POLE 1R10)
10GΩ, 500VDC
6 POLE 1.375 MAX.
8 POLE 1.580 MAX.
4 POLE 1.165 MAX.
#6-32
2 POLE .950 MAX.
SIDE ONLY
-55ºC to 75ºC
1.187 MAX .
1000V
1000V
500V
(30.15)
(34.93)
(40.13)
(38.1)
16
14
13
11
4
4 POLE
(9.53)
.375
12
rms
15
3
rms
rms
9
6
2
10
(3.96)
8
7
5
.156
1
(11.10)
.437
TYPE E6 ONLY
TYPE E6 ONLY
22
19
16
20
17
14
4
6 POLE
12
3
21
18
15
9
6
2
13
11
10
8
7
5
Datasheets and product data is subject to the
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
the ‘Definitions’ section, available at
http://relays.te.com/definitions
http://relays.te.com/definitions
1
Printed circuit terminal dimensions
Other Data
Terminal type
Weight
Packaging/unit
Accessories
For details see datasheet
Product Code Description
Many versions of sockets and clips available.
(TO TOP OF CASE)
(Continued)
CASE R ONLY
Recommend tape tab
be removed after
immersion cleaning
and before relay is put
in service. Peel off to
permit proper relay
ventilation.
26
25
23
22
20
28
19
17
C
D
4
8 POLE
12
15
A
27
24
21
18
3
9
6
2
(continued)
16
13
11
10
B
14
8
7
5
1
Type 2
Type 7
Type 9
Thickness
Solder/plug-in terminals, PCB-THT,
8- or 11-PIN octal type plug
Sockets and Accessories, R10 Relays
.131
.131
.170
.012
A
Datasheets, product data, ‘Definitions’ sec-
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
tion, application notes and all specifications
are subject to change.
are subject to change.
Potter & Brumfield
Potter & Brumfield
tray/50 pcs., box/350pcs.
.050
.040
.040
.012
R10 - AC Coil Diagram
B
23 to 40g
.064
.013
.000
.012
C
DUAL
COIL
1.251
1.187
1.20
.013
D
Staggered
Arrang.
Inline
Inline
–––

Related parts for 27E194