H5CX-A-N AC100-240 Omron, H5CX-A-N AC100-240 Datasheet - Page 45

RELAY TIMER DGTL SPDT 100/240VAC

H5CX-A-N AC100-240

Manufacturer Part Number
H5CX-A-N AC100-240
Description
RELAY TIMER DGTL SPDT 100/240VAC
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-A-N AC100-240

Mounting Type
Panel Mount
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Termination Style
Screw Terminal
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Timing Range
0.001 s to 9999 Hrs
Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Display Type
6 Digit LCD
Product
Digital Timer
Time Range
0.001s-9999hrs
Power Consumption
6.2VA
Reset Time
20ms
Character Size
11.5mm
Time Range Min
0.001s
Supply Voltage Min
100VAC
Connector Type
Screw Terminal
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H5CXANAC100240
Z2997
■ DIP Switch Settings
All functions are set using the DIP switch.
Note 1: All the pins are factory-set to OFF.
■ Operation in Run Mode
Set each digit for the set value using the corresponding
Forecast Value Setting
Absolute Value Setting
1
2
3
4
5
6
7
8
2: DIP switch settings are effective when the power is turned
3: The characters displayed in reverse video are the default set-
Time range
Output mode
Input signal width
NPN/PNP input
mode
Reset Key protec-
tion
Up Key protection
Mode Key protec-
tion
ON again. (Set the DIP switch before installation and power-
up.)
tings.
Item
Present value
Set value
Set value 1
Set value 2
Present value
Present value
Forecast set value
Present value
Refer to the table on the right.
F-1 mode
20 ms
NPN
Disabled
Disabled
Disabled
OFF
Each time the
pressed, the sub-display
will switch between set
value 1 (“SET 1” is lit) and
set value 2 (“SET 2” is lit).
Each time the
pressed, the sub-display will
switch between the set
value (“SET” is lit) and the
forecast set value (“1” is lit).
A mode
1 ms
PNP
Enabled
Enabled
Enabled
ON
Key is
Key is
Keys.
OFF
ON
OFF
ON
Pin 1
OFF
OFF
ON
ON
Pin 2
0.1 h to 99999.9 h
0.01 s to 9999.99 s
0 h 00 min 01 s to 99 h 59 min 59 s
0.1 min to 99999.9 min
OFF
ON
(Default setting)
Time range
1
2
3
4
5
H5CX-B
6
7
8
45

Related parts for H5CX-A-N AC100-240