H3DE-S2 AC/DC24-230 Omron, H3DE-S2 AC/DC24-230 Datasheet - Page 42

RELAY TIMER ANALOG DIN 4 MODE

H3DE-S2 AC/DC24-230

Manufacturer Part Number
H3DE-S2 AC/DC24-230
Description
RELAY TIMER ANALOG DIN 4 MODE
Manufacturer
Omron
Series
H3DEr

Specifications of H3DE-S2 AC/DC24-230

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.1 Sec ~ 120 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24 ~ 230VAC/DC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Screwdriver Slot
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
H3DE-S2 AC/DC 24-230
H3DES2ACDC24230
Z1141
Precautions
J SETTING CHANGES
Note: To avoid malfunction, do not change the time unit, time
J MOUNTING/REMOVING
The H3DE should be mounted as horizontally as possible.
When mounting the H3DE on a socket mounting track, hook
portion (A) of the Timer to an edge of the track first, and then
depress the Timer in the direction of (B).
When removing the H3DE, pull out portion (C) with a flat-blade
screwdriver and remove the Timer from the mounting track.
The H3DE can be mounted and removed easily if a distance of
30 mm (1.18 min) or more is kept between the H3DE and the top
surface of other equipment located below the H3DE.
scale, operating mode, or output type selector switch
while the Timer is in operation.
Rail stopper
(C)
30 mm (1.18 in) min.
(A)
(B)
J POWER SUPPLIES
The H3DE Series is provided with a transformerless power
supply system. An electric shock may be received if the input
terminal or the output type selector switch is touched while power
is being supplied.
Use the bar terminal for wiring the H3DE. Using a stranded-wire
terminal may cause a short-circuit due to a stray wire entering
into the Timer.
Both AC and DC power supplies can be connected to the power
input terminals without regarding polarity.
With the H3DE only, a DC power supply must be connected to
the power input terminals as designated according to the polarity
of the terminals.
A DC power supply can be connected if its ripple factor is 20% or
less and the mean voltage is within the rated operating voltage
range of the Timer.
Connect the power supply voltage through a relay or switch in
such a way that the voltage reaches a fixed value at once or the
Timer may not be reset or a timer error could result.
For the power supply of an input device, use an isolating
transformer, of which the primary and secondary windings are
mutually isolated and the secondary winding is not grounded.
Circuit
Start
input
B1
H3DE
A1
A2
Isolation transformer is required.
Power supply
7