H5F-B Omron, H5F-B Datasheet - Page 4

TIMER DIGITAL DAILY 100-240VAC

H5F-B

Manufacturer Part Number
H5F-B
Description
TIMER DIGITAL DAILY 100-240VAC
Manufacturer
Omron
Series
H5Fr
Datasheets

Specifications of H5F-B

Timing Range
24 Hrs x 7 Days
Supply Voltage
100 V to 240 V
Display Type
LCD Backlight
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H5FB
Z1142

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H5F-B
Manufacturer:
OMRON
Quantity:
300
■ Operation Functions
Note: Both the timer operation and the pulse-output operation cannot be programmed together.
■ Operation When Power Turns OFF
1. The time and settings are backed up using a lithium battery.
2. The display stays ON but the output turns OFF.
3. Settings for all types of operation except override and automatic
Timer operation (ON/OFF operation)
Pulse-output operation
Forced ON/OFF operation
Override and automatic return operation
Partial operation on specified day
Holiday setting
ON time
Regular
program
Operation in
present week
Operation from
next week
Regular
program
Output
operation
Regular
program
Operation on
operation day
Operation on
specified day
return operation are possible.
Operation on
operation day
Start of override and
automatic return operation
Program 1
(special)
Pulse width
OFF time
Program 2
Operation
on holiday
ON time
Controls the output according to preset of ON and OFF times
• Minimum setting unit: 1 min
• Up to 12 ON/OFF operations are possible per day.
Output turns ON for a fixed period (pulse width) at the set time.
• Pulse width: 1 to 59 s, or 1 to 60 min. (The same pulse width setting is used for all types of
• The pulse width can be set in units of 1 s or 1 min.
• Up to 24 pulse-output operations are possible per day.
Forcibly turns ON/OFF the output by the output ON/OFF switch.
Using the output ON/OFF switch and the Write Key, control output is held in the ON state until
the next OFF time.
• It is also possible to hold the control output in the OFF state until the next ON time.
• Operation after the output turns OFF (or ON) will be based on the regular program.
• This function can be used with pulse-output operation.
The Time Switch operates according to only some of the programs on a user-specified day.
(Convenient, for example, for executing a half-day operation on Saturday.)
• It is not possible to set operation to be executed only on the specified day.
• This function can be used with pulse-output operation.
It is possible to set a day in the present week as a holiday (i.e., a non-operation day: output
OFF regardless of the settings). When that day has passed, operation will continue according
to the regular program, and operation will be executed as normal on that day from the follow-
ing week
• This function can be used with pulse-output operation.
output operation.)
H5F
4