H5CX-BWSD Omron, H5CX-BWSD Datasheet - Page 34

TIMER DGTL DUAL 99KHRS 12-24VDC

H5CX-BWSD

Manufacturer Part Number
H5CX-BWSD
Description
TIMER DGTL DUAL 99KHRS 12-24VDC
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-BWSD

Relay Type
Integrated
Function
Programmable (Multi-Function)
Delay Time
0.01 Sec ~ 99K Hrs
Output Type
Transistor
Voltage - Supply
12 ~ 24VDC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Circuit
-
Contact Rating @ Voltage
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
H5CXBWSD
Z2408

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H5CX-BWSD-N
Manufacturer:
OMRON
Quantity:
1 000
Settings for Twin Timer Operation
Run Mode
Function Setting Mode
Present value,
OFF set time
Present value,
ON set time
OFF time range
ON time range
Timer mode
ON/OFF start mode
Input signal width
NPN/PNP input mode
Display color
Key protect level
Parameter name
Parameter name
OFF set time
Present value
ON set time
Present value
---
---
---
---
---
---
---
---
---
---
---
---
---
Parameter
oftr
ontr
timm
totm
iflt
imod
colr
kypt
Parameter
0.00 to 99.99 (Time range: --,--s)
0.0 to 999.9 (Time range: ---,-s)
0 to 9999 (Time range: ----s)
0:00 to 99:59 (Time range: --min--s)
0.0 to 999.9 (Time range: ---,-min)
0 to 9999 (Time range: ----min)
0:00 to 99:59 (Time range: --h--min)
0.0 to 999.9 (Time range: ---,-h)
0 to 9999 (Time range: ----h)
0.000 to 9.999 (Time range: -,---s)
Same as OFF set time above
Same as OFF set time above
Same as OFF set time above
--.--s/---.-s/----s/--min--s/---.-min/----min/
--h--min/---.-h/----h/-.---s
--.--s/---.-s/----s/--min--s/---.-min/----min/
--h--min/---.-h/----h/-.---s
up/down
toff/ton
20ms/1ms
npn/pnp
red/grn/r-g/g-r
kp-1/kp-2/kp-3/kp-4/kp-5
Setting range
Setting range
0.00
0.0
0
0:00
0.0
0
0:00
0.0
0
0.000
Same as left
Same as left
Same as left
Default value
--.--s
--.--s
up
toff
20ms
npn
red
kp-1
Default
value
s
s
s
min; s
min
min
h; min
h
h
s
Same as left
Same as left
Same as left
---
---
---
---
---
---
---
---
Unit
Unit
H5CX-A/-L
Set value
Set value
34