H8GN-AD DC24 Omron, H8GN-AD DC24 Datasheet - Page 3

no-image

H8GN-AD DC24

Manufacturer Part Number
H8GN-AD DC24
Description
TIMER/COUNTER 1/32DIN 24VDC
Manufacturer
Omron
Series
H8GNr
Datasheet

Specifications of H8GN-AD DC24

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H8GN-ADDC24
H8GNADDC24
■ Characteristics
Note: Refer to the Life-test Curve.
Timer function
Insulation resistance
Dielectric strength
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
Ambient humidity
EMC
Approved standards
Case color
Degree of protection
Weight
Malfunction
Accuracy of operating
time and setting error
(including temperature
and voltage effects)
Destruction
Malfunction
Destruction
Mechanical
Electrical
Operating
Storage
Signal start: ± 0.03% ± 30 ms max.
Power-ON start: ± 0.03% ± 50 ms max.
100 MΩ min. (at 500 VDC)
1,500 VAC, 50/60 Hz for 1 min between output terminals and non-current-carrying metal
parts
510 VAC, 50/60 Hz for 1 min between current-carrying terminals (except output terminals)
and non-current-carrying metal parts
1,500 VAC, 50/60 Hz for 1 min between output terminals and current-carrying terminals (ex-
cept output terminals)
500 VAC, 50/60 Hz for 1 min between communications terminals and current-carrying termi-
nals (except output terminals)
1,000 VAC, 50/60 Hz for 1 min between contacts not located next to each other
Square-wave noise by noise simulator;
±480 V (between power terminals), ± 600 V (between input terminals)
± 8 kV (malfunction), ± 15 kV (destruction)
10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min
10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h
100 m/s
300 m/s
10 million operations
100,000 operations min. (3 A at 250 VAC, resistive load) (See note.)
−10°C to 55°C (with no icing or condensation)
−25°C to 65°C (with no icing or condensation)
25% to 85%
(EMI):
Emission Enclosure:
(EMS):
Immunity ESD:
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated,
Immunity Conducted
Disturbance:
Immunity Burst:
Immunity Surge:
UL508, CSA C22.2 No.14
Conforms to EN61010-1/IEC61010-1 (Pollution degree 2/overvoltage category II)
Conforms to VDE0106/P 100 (Finger Protection)
Rear section: Gray smoke; Front section: N1.5 (black)
Panel surface: IP66 and NEMA Type 4X (indoors)
Rear case:
Terminal block: IP20
Approx. 80 g
2
2
, 3 times each in six directions
, 3 times each in six directions
IP20
EN61326
EN55011 Group 1 Class A
EN61326
EN61000-4-2: 4 kV contact discharge (level 2)
EN61000-4-6: 3 V (0.15 to 80 MHz) (level 2)
EN61000-4-4: 2 kV power-line (level 3);
EN61000-4-5: 1 kV between lines
8 kV air discharge (level 3)
80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated,
900 MHz ± 5 MHz) (level 3)
1 kV I/O signal-line (level 4);
1 kV communications-line (level 3)
(power and output lines) (level 3);
2 kV between grounds
(power and output lines) (level 3)
H8GN
3

Related parts for H8GN-AD DC24