69913 Tyco Electronics, 69913 Datasheet - Page 2

no-image

69913

Manufacturer Part Number
69913
Description
DIE SOLIS 69082 400MCM
Manufacturer
Tyco Electronics
Datasheet

Specifications of 69913

Lead Free Status / RoHS Status
Not applicable / Not applicable

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
69913-002LF
Manufacturer:
FCI
Quantity:
198
3.2. Die Removal
4. CRIMPING PROCEDURE
2 of 5
Crimping Die Assemblies 69911, 69912, 69913, and 69914
CAUTION
DANGER
2. Select the correct dies for the wire size being
used. See Figure 2.
3. Loosen locking screw in top section of crimping
head. See Figure 1.
4. Insert shank of stationary die into top section of
crimping head and tighten locking screw.
5. Activate power unit, advance ram until setscrew
is visible.
6. Loosen setscrew and insert shank of moving die
into ram well. Tighten setscrew. See Figure 1.
NOTE
7. Activate power unit to complete cycle and allow
ram to return to DOWN position.
1. Turn off main power switch, disconnect power
unit from power supply.
2. Remove locking screw in top section of crimping
head and remove die. Replace locking screw.
3. Raise ram to full UP position. Loosen setscrew
in ram and remove die.
1. Select the proper size terminal or splice for the
wire size being used.
2. Determine correct terminal or splice wire loading
by referring to CMA range listed in Figure 2. Total
CMA of wires being used must be within CMA
range of terminal or splice.
3. Strip wire as indicted in Figure 2.
4. Ensure that wire range or size stamped on
terminal or splice corresponds with wire size being
used and wire size or range stamped on dies.
5. Center terminal or splice wire barrel in stationary
die as shown in Figure 3. For best results, when
brazed seam on terminal or splice is visible,
position seam toward moving die.
i
!
Be sure that the dies are inserted FULLY and that
the FLATS on the die shanks are facing the
setscrews.
Do not nick conductor strands.
Avoid personal injury. When operating power unit,
exercise caution while holding terminals or wire
near crimping area.
Tyco Electronics Corporation
Terminal
Butt Splice
Parallel
Splice
Parallel
Splice
6. Activate tool so that ram advances and holds
terminal or splice in place. Do not deform terminal
or splice wire barrel.
7. Insert stripped wire into terminal or parallel
splice until end of conductor is flush with or
extended slightly beyond end of wire barrel.
8. Insert stripped wire into butt splice until end of
conductor butts against splice wire stop.
9. Activate tool to complete the crimp.
10. To crimp other half of butt splice, remove it and
reposition uncrimped half in stationary die. Follow
same procedure to crimp first half of splice.
11. For crimp inspection procedure, refer to
Section 5 and Figure 4.
Center 1/2 of Splice
in Stationary Die
Center Terminal
in Stationary Die
Figure 3
Center Splice in
Stationary Die
Brazed Seam Faces
Moving Die
408-2671