Description
DIE PIDG STRATO 69710 22-20AWG
Manufacturer
Tyco Electronics
Datasheet

Specifications of 69732

Lead Free Status / RoHS Status
Not applicable / Not applicable
PIDG Terminal,
PIDG STRATO-THERM
Terminal,
PLASTI-GRIP
Terminal, and
DIAMOND GRIP
Terminal
Insulation Barrel
Section of Crimping
Chamber
PIDG Splice
DIAMOND GRIP
Splice
4 of 11
Wire Barrel Against
Locator
Terminal and Splice Crimping Die Assemblies
Figure 6
Figure 7
Figure 8
Wire Barrel Section of
Crimping Chamber
Window Indent Slid
Over and Down Into
Locator
To Locate PIDG
STRATO-THERM
Terminal, Pull Locator
Down Slightly
Wire Barrel
Against Locator
Window Indent Slid
Over Locator
Locator
Locator
Locator
Tyco Electronics Corporation
4.2. PLASTI-GRIP Terminal
The insulation crimping section of the moving die has
three crimp positions: 1–Tight, 2–Medium, 3–Loose.
Adjust the insulation crimp as follows:
NOTE
2. Insert the moving die into the die holder. Turn
the die holding screw enough to hold the die firmly
in place. DO NOT tighten the die holding screw at
this time.
3. Insert an UNSTRIPPED wire into ONLY the
insulation barrel of the terminal or splice.
4. Make a test crimp . Close the moving die on the
terminal or splice and hold the moving die in the
bottomed position. Tighten the die holding screw
while the dies are bottomed, then complete the
crimping cycle.
5. Remove the terminal or splice from the dies,
and check the insulation grip by bending the wire
back and forth ONCE. The terminal sleeve should
retain the grip on the wire insulation. If the wire
pulls out, set the insulation crimp adjustment to the
next tighter position as follows:
6. With both adjustment spacers placed between
the moving die and the die holder, the die is set in
the tightest insulation crimping position. Number 1
will appear on the corner of the top spacer.
NOTE
1.Use Position 3 for wire having a large insulation
diameter. Remove the moving die from the die
holder. Turn both insulation adjustment spacers so
that they fit into the notch in the side of the die.
See Figure 1.
2. Use Position 2 for wire having a medium
insulation diameter. Remove the moving die from
the die holder. Turn the lower insulation adjustment
spacer 90 _ so that it fits between the moving die
and the die holder. No. 2 will appear on the corner
of the spacer nearest the color code dot.
i
i
a. Remove the moving die from the die holder.
b. Turn the lower insulation adjustment spacer
90 _ so that it fits between the moving die and
the die holder. Number 2 will appear on the
corner of the spacer.
c. Repeat the test crimp and adjust the moving
die as necessary until the desired insulation grip
is obtained.
The moving die must be removed from the die
holder to make this adjustment.
PLASTI-GRIP terminals feature a wire insulation
support only.
408-1632