ZX-EDA11 2M Omron, ZX-EDA11 2M Datasheet - Page 7

AMP UNIT 12-24VDC PWR SPLY NPN

ZX-EDA11 2M

Manufacturer Part Number
ZX-EDA11 2M
Description
AMP UNIT 12-24VDC PWR SPLY NPN
Manufacturer
Omron
Datasheets

Specifications of ZX-EDA11 2M

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ZX-EDA112M
ZXEDA112M
I/O Circuit Diagrams
NPN Amplifier Unit: ZX-EDA11
Connections: Amplifier Unit
Note 1. Use a separate stabilized power supply for the Amplifier Unit,
2. Wire the Unit correctly. Incorrect wiring may result in damage
3. Use the blue (0-V) line for the power supply and use the
particularly when high resolution is required.
to the Unit. (Do not allow wiring, particularly the linear output,
to come into contact with other lines.)
shield wire (linear output ground) together with the black (lin-
ear output) line for linear output. Each of these grounds must
be used for the designed purpose. When not using the linear
output, connect the linear output ground to the 0-V ground.
Current/voltage
switch
100 Ω
Voltage output
±4V
Current output
4 to 20 mA
Orange
Purple
Brown: 12 to 24 VDC
Blue: GND (0V)
Purple: Timing input
Orange: Zero reset input
Red: Reset input
Black: Linear output
Shield: Linear GND
Brown
Green
Shield
Pink: Judgement output hold input
White
White:
HIGH judgement output
Green:
PASS judgement output
Gray:
LOW judgement output
Black
Gray
Blue
Pink
Red
12 to 24 VDC
GND (0V)
HIGH judgement output
PASS judgement output
LOW judgement output
Linear output
Linear output GND
Judgement output hold input
Zero reset input
Timing input
Reset input
ZX-E Series
Current output: 300 Ω max.
Voltage output: 10 kΩ min.
12 to 24 VDC
Smart Sensors (Inductive Displacement Type)
PNP Amplifier Unit: ZX-EDA41
Current/voltage
switch
100 Ω
Current output
4 to 20 mA
Voltage output
±4V
Brown: 12 to 24 VDC
Blue: GND (0V)
Pink: Judgement output hold input
Purple: Timing input
Orange: Zero reset input
Red: Reset input
Black: Linear output
Shield: Linear GND
White:
HIGH judgement output
Green:
PASS judgement output
Gray:
LOW judgement
output
Current output:
300 Ω max.
Voltage output:
10 kΩ min.
12 to
24 VDC
7