D10DNFP BANNER ENGINEERING, D10DNFP Datasheet - Page 7

Photoelectric Sensor

D10DNFP

Manufacturer Part Number
D10DNFP
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Dual Discrete Outputr
Datasheets

Specifications of D10DNFP

Sensor Output
NPN
Sensor Input
Fiber Optic
Output Type
Transistor
Contact Current Max
150mA
Switch Terminals
Connector
Body Style
Rectangular
Brand/series
Expert™
Current, Switching
150 mA
Function
Fiber Optic
Indicator
LCD
Ip Rating
IP50
Material, Casing
Black ABS⁄Polycabonate Alloy (Housing)
Material, Cover
Polycarbonate
Mounting Type
DIN Rail
Output
NPN
Primary Type
Photoelectric
Sensing Mode
Selectable
Technology
Photoelectric
Temperature, Operating
-20 to +55 °C
Termination
Cable
Time, Response
50 μs, 200 μs, 1 ms, 2.5 ms
Voltage, Supply
24 VDC
Accessories Available
Cordsets and Plastic Fiber Optic Cable
Fiber Optic Sensor Type
Dual Discrete Output
Lead Free Status / Rohs Status
RoHS Exempt Product
Figure 7. Single-Point Light SET (Dark
Figure 8. Light SET Threshold Offset
(no signal)
(no signal)
(no signal)
Super High-Speed
High-Speed
High-Power
Super High-Power
Darkest
Darkest
Darkest
threshold slightly above
the presented condition
Banner Engineering Corp.
Output OFF
www.bannerengineering.com • Tel: 763.544.3164
Mode
Sensor positions
Output OFF
Output ON
Operate shown)
• P ress and hold
• P resent Output
• F our-click
0.04 seconds ≤ “Click” ≤ 0.8 seconds
Static push button
> 2 seconds
OFF condition
Static push
button
Presented
Condition
Threshold position
Threshold position
Manual Adjust
Manual Adjust
adjusted by
adjusted by
Output ON
Presented
Condition
Push Button
taught signal value)
Condition
Presented
Threshold Offset
(counts below
Sensor positions
threshold slightly below
the presented condition
Output OFF
Minneapolis, MN U.S.A.
Output ON
Output OFF
30
22
9
6
T
T
T
Most Light
Most Light
Most Light
(saturated
(saturated
(saturated
signal)
signal)
signal)
• S ingle-pulse
• P resent Output
• F our-pulse remote line
T
remote line
OFF condition
0.04 seconds ≤ T ≤ 0.8 seconds
• S ets a threshold slightly below the taught condition (see Figure 7)
• A ny condition darker than the threshold condition causes the output to change state
• T hreshold position is adjustable using “+” and “-” buttons (see Manual Adjust, page 9)
• R ecommended for applications where only one condition is known, for example a stable light
A single sensing condition is presented, and the sensor positions a threshold slightly below
the presented condition. When a condition darker than the threshold is sensed, the output
either turns ON or OFF, depending on the Light/Dark Operate setting (see Sensor Setup, page
10).
Light SET and Light/Dark Operate Selection
Light SET teaches the Output OFF condition and forces the sensor into Dark Operate (DO)
mode. The sensor can be reconfigured to Light Operate (LO) mode after the condition has
been taught (see Sensor Setup, page 10).
background with varying darker targets.
T T T
T
T
Remote Line
T
T
T
T
T
T
T
T
T
T
T
T
T
D10 Expert
T
T
T
• Display flashes “1st”
• Arrow icon turns red
• Display flashes “2nd”
• Arrow icon turns red
Threshold Condition Accepted
• D isplay flashes “sngl” then “Lt” twice
• S ensor returns to RUN mode with new settings
• Arrow icon turns green
Threshold Condition Unacceptable
• Display flashes “fail” and returns to “1st”
• Arrow icon remains red
• A fter 60 seconds, sensor returns to RUN mode
T
(Arrow icon turns green) without changing
settings
T
T
Single-Point Light SET
T
T
T T T
T
T
T
T
T
T
T
T
T
T
T
Dual Discrete Outputs
T
Push Button
T
Remote
T
Result
T
T
T
T
T
T
T
T
T
P/N 64154 rev. F
7