FT-6V PANASONIC EW, FT-6V Datasheet

no-image

FT-6V

Manufacturer Part Number
FT-6V
Description
FIBER-OPTIC SENSOR
Manufacturer
PANASONIC EW
Type
Thrubeamr
Datasheet

Specifications of FT-6V

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PHOTOELECTRIC SENSOR
DIGITAL FIBER SENSOR
FX-300
SERIES
Conforming to
UL Recognition
EMC Directive
Constant advances achieving the highest
level of performance in its class

Related parts for FT-6V

FT-6V Summary of contents

Page 1

Constant advances achieving the highest level of performance in its class PHOTOELECTRIC SENSOR DIGITAL FIBER SENSOR FX-300 Conforming to EMC Directive SERIES UL Recognition ...

Page 2

The FX-300 series of next-generation fiber sensors provides the highest level of sensing performance in its class ‘Stable sensing’, ‘high sensing performance’, ‘easy operation’, ‘improved ease of maintenance’ and ‘preservation of the environment’ are the five concepts underlying the new ...

Page 3

APC circuit has been added, in addition to the four-chemical emitting element. Concept 1 High Stability Concept 5 Eco-friendly Lead-free solder used is gentle on the environment. Full range of fibers Guide for each industry P.9 LCD • Semiconductor / ...

Page 4

High Stability Double coupling lens Stable sensing over long and short periods In addition to a ‘four-chemical emitting element’ which suppresses changes in the light emitting element over time so that a stable level of light emission can be maintained ...

Page 5

Superior Performance Light-emitting amount selection If the light receiving level becomes saturated during close- range sensing or when sensing transparent or minute objects, you can adjust the light emitting amount of the sensor to stabilize sensing without needing to change ...

Page 6

... When output 1 threshold value teaching is carried out with the FX-305, output 2 is set concurrently with the setting shifted by the amount of surplus. Drops in surplus amounts of light intensity due to dust or other particles can therefore be detected and output ...

Page 7

... Depressing the large MODE key sets the ‘mode selection’ and ‘mode cancel’ functions. The large jog switch is used to select from the detailed functions available within each mode, as well as to change numerical values after the mode has been chosen. ● Large MODE key ● ...

Page 8

Easy Maintenance Communication unit improves equipment starting up and maintenance upstream communication unit SC-GU1-485 The communication unit enables inputs to the digital fiber sensors (such as teaching and data bank switching carried out via a PLC, and also ...

Page 9

... SUNX promotes the use of lead-free materials in all of its sensor manufacturing processes including those used for the FX-300 series of digital fiber sensors. Selectable cable length Used for intermediate terminal block Made available are 3 lengths 3.281 ft 6.562 ft, and 5 m 16.404 ft, to suit Directly connected to the PLC your application require- ments ...

Page 10

... The light amount becomes stable a short period after the power is turned on, so setup time can be reduced. ● Stable sensing comparison FX-301(-HS) ...

Page 11

... Extra width Liquid absent 500 460 Liquid present 40 Extra display width has been increased! FT-Z802Y, FD-F705, FT-F902 Detecting leak liquid in cleaning tank (Note) Leak FD-F705 Leak detection fiber FD-F705 The unique effect of capillarity enables reliable detection of small leaks and viscous liquids ...

Page 12

... Actual digit difference: C’ amount , A changed , B FX-301(-HS), FX-305 Light emitting amount selection function makes steps such as those at left unnecessary. FD-L43/L45 FD-L43/L45 Alignment / Convergent reflective type FD-L43, FD-L45 Even glass substrates with 8 (FD-L45 flexure can be stably sensed. • High flexure of 8 (FD-L43) • ...

Page 13

... Carry out limit teaching ‘ ’ before the sensing object (glass substrate) arrives (while there is no sensing object present). When the shift value is set beforehand, the threshold value is set to a value that level 5 % lower than the incident light intensity during teaching. ...

Page 14

FOR ELECTRONIC COMPONENT • AUTOMATIC ASSEMBLY INDUSTRY High-speed response 35 ¨s These digital fiber sensors have the fast response time of 35 !s. They are ideal for sensing minute objects that are moving at high speeds. Interference prevention up to ...

Page 15

... The allowable bending radius 0.157 0.039 in for the FT-WZ8 ). This allows the fibers to be routed with great freedom and uses less space. Because it is installed with only two M2 screws, light beam axis alignment is easy. A front sensing type, side sensing type and top sensing type are provided ...

Page 16

... FR-WKZ11, FR-KZ21/22 H5.2 D15 mm W0.374 H0.205 D0.591 R0.039 in making it space efficient. FT-V10 Chemical-resistant fiber With the case made of PFA (fluorine resin) and fiber sheath with PFA (fluorine resin), the fiber can be used with various types of chemical liquids. FT-P81X, FD-P81X, FD-G6X in. FT-Z802Y ...

Page 17

... PNP open-collector transistor NPN open-collector transistor Red LED PNP open-collector transistor FX-300 Quick-connection cables Model No. Length CN-73- 3.281 ft CN-73- 6.562 ft CN-73- 16.404 ft CN-71- 3.281 ft CN-71- 6.562 ft CN-71- 16.404 ft CN-74- 3.281 ft CN-74- 6.562 ft CN-74- 16.404 3.281 ft CN-72-C1 CN-72- 6.562 ft CN-72- 16.404 ft 16 ...

Page 18

... Description 3.281 ft 2 0.15 mm 4-core cabtyre cable, with connector on one end 6.562 ft Cable outer diameter: "3.0 mm "0.118 in 16.404 ft 3.281 ft 2 0.15 mm 2-core cabtyre cable, with connector on one end 6.562 ft Cable outer diameter: "3.0 mm "0.118 in 16.404 ft Description When cascading multiple amplifiers, or ...

Page 19

... R0.157 in FT-P80 opaque object Flexible 9.055 "0. R10 mm "0.0020 in FT-P81X R0.394 in 3.281 ft opaque object "0. "0.0016 in R0.157 in FT-P60 2 m opaque object 6.562 ft Flexible "0.06 mm 7.874 "0.0024 in FT-WR80 opaque object R0.039 in 16.535 "0.04 mm 6.562 ft 7.874 "0.0016 in FT-WR80L 8.268 opaque object "0.04 mm R25 mm " ...

Page 20

... R5 mm "0.0008 in R0.197 in opaque object 1 m 3.281 ft 800 31.496 "0.05 mm 340 13.386 "0.0020 in 350 13.780 opaque object 2 m 140 5.512 6.562 ft 2.559 2.756 R25 mm R0.984 in 125 4.921 2.362 1 m 2.480 "0.02 mm 3.281 ft "0.0008 in 2.362 opaque object 2 m 6.562 R0.039 in Model No. ...

Page 21

... FT-KV1 R0.394 in opaque object R1 mm FT-WA30 R0.039 in 3,500 137.795 "0.3 mm 3,000 118.110 "0.012 in 3,500 137.795 opaque object R10 mm FT-A30 R0.394 6.562 FT-WA8 R0.039 in 1,100 43.307 "0.25 mm 1,080 42.520 "0.010 in 750 29.528 opaque object R10 mm FT-A8 R0.394 in 8.661 Horizontal: "0.025 mm FT-AFM2 " ...

Page 22

... This is the fiber length (fixed length) for heat-resistant fibers. The ordinary-temperature fibers are free-cut The ordinary-temperature fiber is R25 mm 6) Heat-resistant joint fibers and ordinary-temperature fibers (FT-FM2) are sold as a set. Please refer to ‘Heat-resistant joint fibers catalog’ for details. 7) The allowable cutting range is 500 mm 8) Sold as a set comprising vacuum type fiber for details ...

Page 23

... R25 mm R0.984 in FD-FM2 Fiber FD-FM2S R25 mm R0.984 Sleeve "0.02 mm 6.562 ft "0.0008 in R10 mm FD-FM2S4 R0.394 in gold wire R1 mm FD-W8 R0.039 R0.157 in FD-P80 Flexible 1 m R10 mm FD-P81X 3.281 ft R0.394 in "0.02 mm R25 mm "0.0008 in FD-R80 2 m R0.984 in gold wire 6.562 ft in] as the object. 3.937 in 22 ...

Page 24

... R0.394 in (Note 5) R25 mm R0.984 in "0.04 mm 500 mm R10 mm "0.0016 in R0.394 in 19.685 in gold wire "0.02 mm R25 mm "0.0008 in R0.984 in gold wire 1 m 3.281 ft (FD-T80, FD-WT8: 400 400 mm 15.748 15.748 100 mm 3.937 3.937 in)] as the object. Model No. FD-T80 FD-NFM2 FD-NFM2S FD-NFM2S4 FD-W44 FD-WT8 FD-WG4 FD-G4 ...

Page 25

... R25 mm FD-SFM2SV2 R0.984 in "0.3 mm R25 mm "0.012 in FD-L46 4 m R0.984 in gold wire 13.123 ft FD-L45 3 m 9.843 (LCD glass) R0.157 in FD-L43 2 m 6.562 ft FD-L44 "0.03 mm R10 mm "0.0012 R0.394 in gold wire 6.562 ft FD-L44S "1 "0.075 in FD-WL41 R0.039 in metal pipe (gray) "0.06 mm "0.024 in FD-L41 2 m gold wire 6 ...

Page 26

... R25 mm "0.0008 R0.984 in gold wire 6.562 ft 3.071 "0.02 mm R25 "0.0008 in R0.984 in 6.562 ft gold wire Protective tube R40 R1.575 in Fiber 6.562 ft R15 mm (Note 5) R0.591 in (Liquid) 0.039 to 0.118 in] R10 R0.394 in 6.562 ft 0.039 in] (FD-WKZ1, FD-AFM2, FD-AFM2E: 400 400 mm 15.478 Model No. FD-WZ4 FD-WZ4HB FD-WZ7 ...

Page 27

... Cannot use Cannot use 400 mm 15.748 15.748 in 100 t 0.7 mm 3.937 3.937 photo-terminal (FV-BR1) fiber at atmospheric side (FT-J8). Please refer to ‘Vacuum resistant fiber Photo-terminal FV-BR1 (one pair set) • • RF-003 RF-13 fiber, Gray) mixed fiber, Black / Gray) • FX-AT2 ...

Page 28

... FT-E22 10 0.394 Note: The sensing ranges are in H-SP mode. The sensing ranges in FAST, STD, S-D and LONG modes are the same as for the FX-301. (Refer to p.18l) Sensing range for FX-301B/G/H (Typical model) FT-B8 FT-FM2 FT-NFM2 FT-V10 LONG 220 8.661 150 FX-301B ...

Page 29

... Be careful when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult. Especially when installing a fiber with many cores (sharp bending fibers and heat-resistant glass fiber), please be sure to use it only after you have adjusted it sufficiently. ...

Page 30

... M3 threaded head fiber) Vertical mounting type The free-cut type fiber can be easily cut. Accessory. FX-CT1 is attached with the FT-P80 or the FD-P80. The FX-CT2 is provided with fibers other than this. This is the attachment for the fixed length fiber. (Accessory) This is the attachment for the "2.2 mm " ...

Page 31

... units are connected 158 F Red LED 2 65.617 ft for units) is possible with 0 more, cable. 6.562 ft), CN-73-C5 (Cable length 5 m 16.404 6.562 ft), CN-71-C5 (Cable length 5 m 16.404 6.562 ft), CN-74-C5 (Cable length 5 m 16.404 6.562 ft), CN-72-C5 (Cable length 5 m 16.404 V) ft) ft) ft) ...

Page 32

FX-300 I/O CIRCUIT DIAGRAMS FX-301(-HS) NPN output type Color code D (Brown) V (Note 1) Load (Black) Output Tr 100 mA max. (Note (Blue (Note 1) Internal circuit Users’ circuit Notes: 1) The quick-connection sub ...

Page 33

... The incident light intensity in the digital display and the 7 setting is complete. Notes not move or bend the fiber cable after the sensitivity setting. Detection may become unstable case of using the reflective type fibers, if Jog switch is pressed in the object absent condition at 2 and 3, the sensitivity is set to the maximum. ...

Page 34

... When the emission halt of the emitting power switching function is set from ‘OFF’ to ‘ON’, the output may be unstable. Do not use the output control for 0.5 sec. after starting emission. • Make sure that the power supply is off while wiring. ...

Page 35

... Timer selection method Previous version unit: Timer type was changed using PRO1 mode. The ‘TIMER’ After change: The type of timer can be changed using the ‘TIMER’ function in NAVI mode. 2. Checking threshold value in RUN mode The threshold values can be checked by turning the jog switch. ...

Page 36

FX-300 DIMENSIONS (Unit: mm in) FX-301 Amplifier FX-305 Notes: 1) FX-305 ; Output 1 operation indicator (Orange) 2) FX-305 ; Output 2 operation indicator (Orange) 3) FX-301 ; 3-pin, FX-305 ; 4-pin CN-73-C Main cable (Optional) CN-74-C • Length (L) ...

Page 37

... Time Pass 2 Initial setting Threshold value resetting again Threshold value setting Sensing not possible m When limit teaching is used, use the SHIFT function in PRO mode of the amplifier to set the shift amount beforehand. Quick-connection cable CN-73-C (Optional) • Mode selection The MODE wire can be ...

Page 38

... S1 t1 PNP input type S2 FX-CH2 Ripple P less t2 less than 2 sec. (This is the timing period for 1 level. 2 levels are required 0.5 sec. or more (Sampling starts after 0.5 sec.) Notes: 1) Low Sink current 0 Input impedance 10 kΩ approx. High 0.6 V DC, or open ...

Page 39

Upper Communication Unit for Digital Sensors / SC-GU1-485 Conforming to EMC Directive We now offer remote maintenance for sensors! Also reduces the work required to the system to start running! Centralized control and setting of scattered digital sensors (FX-301/305) is ...

Page 40

... Conditions of use • SUNX does not guarantee the correct operation of this software. SUNX takes no responsibility for any direct or indirect losses, damage, loss of profit or any other problems arising as a result of using or operating this software. End unit (Accessory) 64 ...

Related keywords