FT-6V PANASONIC EW, FT-6V Datasheet - Page 8

no-image

FT-6V

Manufacturer Part Number
FT-6V
Description
FIBER-OPTIC SENSOR
Manufacturer
PANASONIC EW
Type
Thrubeamr
Datasheet

Specifications of FT-6V

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
7
Easy Maintenance
Communication unit improves equipment starting up and maintenance
upstream communication unit SC-GU1-485
The communication unit enables inputs to
the digital fiber sensors (such as teaching
and data bank switching) to be carried out
via a PLC, and also allows confirming of the
incident light intensity an output status for
the fiber sensors. This greatly improves
workability during equipment starting up
and maintenance.
External input unit FX-CH2
Teaching and data bank switching for up to
a maximum of 16 digital fiber sensors
(FX-301 and FX-305) can be carried out all
at once using an external device such as a
PLC, touch screen or switch.
We now offer remote maintenance for sensors!
Also reduces the work required to the
system to start running!
Support for stable sensing and smooth setup changes!
Digital fiber sensor settings can be changed using
input from a touch screen or switch, so that
production line setup changes can be carried out
more easily.
Teaching input
Data bank switching input
Key lock setting input
<
The sensor settings and
operation
checked on the touch
screen, greatly improving
ease of operation!
Touch screen monitor example
Device A monitor
L i n e 1
The key lock function that prevents incorrect
operations by operators can be set on and off.
Setup changes
Loader A
Switching between 3 channels of data banks
and loading and saving of all channels at once
can be carried out.
FX-CH2 function list
Tank A
External teaching
Data bank switching
The following types of external teaching can be carried out.
● Full-auto teaching ● Limit teaching ‘
● Limit teaching ‘
Full-auto teaching is recommended for
teaching when the sensing object is changed
without stopping the line.
Settings such as output operations (L-ON /
D-ON) and timer operations can be recorded
in the digital fiber sensor’s data bank and
switching can be carried out externally.
m Up to 3 files can be stored.
L i n e 2
Liquid level detection sensor 1
Liquid level detection sensor 2
Passage confirmation sensor
Mapping sensor
can
L i n e 3
Menu
L i n e 4
be
Incident light
intensity
(external automatic teaching / data bank switching)
’ ● 2-level teaching
Back
Output
Ideal for workplaces such as
semiconductor
manufacturing lines where
there are restrictions on
operators entering and exiting
[Communicable commands]
>
Sensor incident
light intensity
Sensor settings
verification
Sensor output status
Threshold value
settings, etc.
and
LCD
Easy Maintenance
COM.
S1
S2
S3
Control and settings can be carried out remotely
Connector for input device
CN-EP1 [1 pc. included with FX-CH2(-P)]
Setting and confirming incident light intensity for digital
fiber sensors (FX-301/305) that are scattered inside and
outside equipment can be carried out remotely for all
sensors by using the SC-GU1-485, which greatly improves
ease of operations such as monitoring equipment that is
running and also equipment starting and maintenance.
To PLC or PC
(
communication
Product lineup
Concept 4
RS-485
External input unit FX-CH2(-P)
)
Main unit
End unit
Digital fiber sensor
FX-301, FX-305
FX-301
FX-301
Quick-connection cable
CN-73-C (optional)
power supply
FX-305
FX-305
24 V DC
MODE
0 V
V