FT-6V PANASONIC EW, FT-6V Datasheet - Page 39

no-image

FT-6V

Manufacturer Part Number
FT-6V
Description
FIBER-OPTIC SENSOR
Manufacturer
PANASONIC EW
Type
Thrubeamr
Datasheet

Specifications of FT-6V

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control and settings can be carried out remotely
Setting and checking incident light intensity for digital
sensors (FX-301/305) that are scattered inside and outside
equipment can be carried out remotely for all sensors by
using the SC-GU1-485, which greatly improves ease of
operations such as monitoring equipment that is running and
also equipment starting and maintenance.
Note: Used when the output signal is sent via a SC-GU1-485 to the PLC. If
Less wiring and installation work
Up to a maximum of 16
sensors can be connected
side by side. Power can be
supplied to all of them at
once, so that less wiring and
installation work is required.
Wire-saving connectors also
makes it possible to send
output signals to the PLC in
a single batch.
Upper Communication Unit for Digital Sensors / SC-GU1-485
We now offer remote maintenance for sensors!
Also reduces the work required to the system
to start running!
Centralized control and setting of scattered digital sensors
(FX-301/305) is possible using a PLC or personal computer
(RS-485 communication)
Conforming to
EMC Directive
To PLC or PC
the output signal is sent directly to the PLC, a quick-connection cable
(CN-72-C , CN-71-C ) should be used.
<
[
commands
The sensor settings and operation can be checked on
the touch screen, greatly improving ease of operation!
Applicable digital sensor
Fiber sensor FX-301 (Updated version), FX-305
Communicable
semiconductor and LCD manufacturing lines where there
Touch screen monitor example
Device A monitor
Li n e1
Loader A
Tank A
are restrictions on operators entering and exiting
Main unit
(SC-GU1-485)
Li ne 2
Ideal for workplaces such as
End unit (SC-GU1-EU: Accessory)
]
Liquid level detection sensor 1
Liquid level detection sensor 2
Passage confirmation sensor
Mapping sensor
Sensor incident light intensity
Sensor settings verification
Sensor output status
Threshold value settings, etc.
Li ne3
Menu
Li ne 4
Incident light
intensity
>
24 V DC power supply
Back
Output
Terminal block is not required for signal
transmission via RS-485 communication
Unified power supply
Link cable
(SC-GU1-CC02: Accessory)
Wire-saving connector (Note)
(CN-701: Optional)
Quick-connection cable
(CN-73-C2: Accessory)
Example of use in semiconductor
cleaning process
Communication speed 57.6 kbps
High-speed communication at a maximum speed of
57.6 kbps allows the operator to instantly check information
such as the incident light intensity and output statuses of the
digital sensors.
High general applicability so that any type of PLC can be used
RS-485 communication provides a high level of general
compatibility so that any type of PLC can be used. Integration with
existing systems is possible without the need to change PLCs.
Series connection of a maximum of 31 nodes is possible
A maximum of 31 nodes can be connected in series. This is
ideal for flexible handling when the sensors are to be
installed in scattered locations or if more sensors are added.
Pipe-mountable
liquid level detection fiber
1 node
RS-485 communication
Contact type liquid
level detection fiber
2 node
Compatible with all PLCs
equipped with RS-485
compatible units
3 node
Chemical-resistant
fiber
Max. 31 node
4 node
38