S701G25N3S EATON CUTLER HAMMER, S701G25N3S Datasheet - Page 50

Motor Starter

S701G25N3S

Manufacturer Part Number
S701G25N3S
Description
Motor Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of S701G25N3S

No. Of Phases
Three
Power Rating
20hp
Current Rating
25A
Peak Reflow Compatible (260 C)
No
Output Current
25A
Supply Voltage Max
600VAC
Control Voltage Max
300V
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39.2
IT. Soft Starters—S801, continued
Description
Max. current capacity
General Information
Bypass mechanical lifespan
Insulating voltage Ui
Ramp time range
Resistance to vibration
Resistance to shock
Electrical Information
Operating voltage
Operating frequency
Overload setting
Trip class
Cabling Capacity (IEC 947)
Number of conductors
Wire sizes
Type of connectors
Control Wiring (12-Pin)
Wire sizes in AWG
Number of conductors (stranded)
Torque requirements in lb-in
Solid, stranded or flexible max. size in mm
Control Power Requirements
Voltage range (24V ±10%)
Steady-state current amps
Inrush current amps
Ripple
Relays (1) Class A and C
Voltage AC—maximum
Voltage DC—maximum
Amps—maximum
Environment
Temperature—operating
Temperature—storage
Altitude
Humidity
Operating position
Pollution degree IEC947-1
Impulse withstand voltage IEC947-4-1
Notes
50
U-Frame 500A unit does not have IEC certification.
UL recognized component.
Control Products Catalog CA08102001E—September 2010 www.eaton.com
Reduced Voltage Motor Starters
Solid-State Starters
2
S801 Soft Starter (Partial Catalog Number)
S801T18
180
10M
660V
0.5–180 seconds
(0.5–360 seconds extended ramp)
3g
15g
200–600V
47–63 Hz
30–100%
5, 10, 20 and 30
1 or 2
4 AWG to 500 kcmil
Add-on lug kit
22–14
2 (or one AWG 12)
3.5
3.31
21.6–26.4
1.0
10
1%
240
120
3
–30 to 50°C (no derating) consult
factory for operation >50°C
–50 to 70°C
<2000m—consult factory
for operation >2000m
<95% noncondensing
Any
3
6000V
S801T24
240
10M
660V
0.5–180 seconds
(0.5–360 seconds extended ramp)
3g
15g
200–600V
47–63 Hz
30–100%
5, 10, 20 and 30
1 or 2
4 AWG to 500 kcmil
Add-on lug kit
22–14
2 (or one AWG 12)
3.5
3.31
21.6–26.4
1.0
10
1%
240
120
3
–30 to 50°C (no derating) consult
factory for operation >50°C
–50 to 70°C
<2000m—consult factory
for operation >2000m
<95% noncondensing
Any
3
6000V
S801T30
304
10M
660V
0.5–180 seconds
(0.5–360 seconds extended ramp)
3g
15g
200–600V
47–63 Hz
30–100%
5, 10, 20 and 30
1 or 2
4 AWG to 500 kcmil
Add-on lug kit
22–14
2 (or one AWG 12)
3.5
3.31
21.6–26.4
1.0
10
1%
240
120
3
–30 to 50°C (no derating) consult
factory for operation >50°C
–50 to 70°C
<2000m—consult factory
for operation >2000m
<95% noncondensing
Any
3
6000V
S801U36
360
10M
660V
0.5–180 seconds
(0.5–360 seconds extended ramp)
3g
15g
200–600V
47–63 Hz
30–100%
5, 10, 20 and 30
1 or 2
4 AWG to 500 kcmil
Add-on lug kit
22–14
2 (or one AWG 12)
3.5
3.31
21.6–26.4
1.0
10
1%
240
120
3
–30 to 50°C (no derating) consult
factory for operation >50 C
–50 to 70°C
<2000m—consult factory
for operation >2000m
<95% noncondensing
Any
3
6000V

Related parts for S701G25N3S