Specifications of S701G25N3S

No. Of Phases
Three
Power Rating
20hp
Current Rating
25A
Peak Reflow Compatible (260 C)
No
Output Current
25A
Supply Voltage Max
600VAC
Control Voltage Max
300V
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39.2
IT. Soft Starters—S801, continued
Description
Max. current capacity
Dimensions
Width in inches (mm)
Height in inches (mm)
Depth in inches (mm)
Weight in lbs (kg)
General Information
Bypass mechanical lifespan
Insulating voltage Ui
Ramp time range
Resistance to vibration
Resistance to shock
Electrical Information
Operating voltage
Operating frequency
Overload setting
Trip class
Cabling Capacity (IEC 947)
Number of conductors
Wire sizes
Type of connectors
Control Wiring (12-Pin)
Wire sizes in AWG
Number of conductors (stranded)
Torque requirements in lb-in
Solid, stranded or flexible max. size in mm
Control Power Requirements
Voltage range (24V ±10%)
Steady-state current amps
Inrush current amps
Ripple
Relays (1) Class A and C
Voltage AC—maximum
Voltage DC—maximum
Amps—maximum
Environment
Temperature—operating
Temperature—storage
Altitude
Humidity
Operating position
Pollution degree IEC947-1
Impulse withstand voltage IEC947-4-1
Note
52
UL recognized component.
Control Products Catalog CA08102001E—September 2010 www.eaton.com
Reduced Voltage Motor Starters
Solid-State Starters
2
S801 Soft Starter (Partial Catalog Number)
S801V50
500
11.03 (280.2)
16.57 (420.8)
7.23 (183.7)
103 (46.8) with lugs
91 (41.4) without lugs
10M
660V
0.5–180 seconds (0.5–360
seconds extended ramp)
3g
15g
200–600V
47–63 Hz
30–100%
5, 10, 20 and 30
2, 4 or 6
2/0 to 500 kcmil
Add-on lug kit
22–14
2 (or one AWG 12)
3.5
3.31
21.6–26.4
1.4
10
1%
240
120
3
–30 to 50°C (no derating)
consult factory for
operation >50°C
–50 to 70°C
<2000m—consult factory for
operation >2000m
<95% noncondensing
Any
3
6000V
S801V65
650
11.03 (280.2)
16.57 (420.8)
7.23 (183.7)
103 (46.8) with lugs
91 (41.4) without lugs
10M
660V
0.5–180 seconds (0.5–360
seconds extended ramp)
3g
15g
200–600V
47–63 Hz
30–100%
5, 10, 20 and 30
2, 4 or 6
2/0 to 500 kcmil
Add-on lug kit
22–14
2 (or one AWG 12)
3.5
3.31
21.6–26.4
1.4
10
1%
240
120
3
–30 to 50°C (no derating)
consult factory for
operation >50°C
–50 to 70°C
<2000m—consult factory for
operation >2000m
<95% noncondensing
Any
3
6000V
S801V72
720
11.03 (280.2)
16.57 (420.8)
7.23 (183.7)
103 (46.8) with lugs
91 (41.4) without lugs
10M
660V
0.5–180 seconds (0.5–360
seconds extended ramp)
3g
15g
200–600V
47–63 Hz
30–100%
5, 10, 20 and 30
2, 4 or 6
2/0 to 500 kcmil
Add-on lug kit
22–14
2 (or one AWG 12)
3.5
3.31
21.6–26.4
1.4
10
1%
240
120
3
–30 to 50°C (no derating)
consult factory for
operation >50°C
–50 to 70°C
<2000m—consult factory for
operation >2000m
<95% noncondensing
Any
3
6000V
S801V85
850
11.03 (280.2)
16.57 (420.8)
7.23 (183.7)
103 (46.8) with lugs
91 (41.4) without lugs
10M
660V
0.5–180 seconds (0.5–360
seconds extended ramp)
3g
15g
200–600V
47–63 Hz
30–100%
5, 10, 20 and 30
2, 4 or 6
2/0 to 500 kcmil
Add-on lug kit
22–14
2 (or one AWG 12)
3.5
3.31
21.6–26.4
1.4
10
1%
240
120
3
–30 to 50°C (no derating)
consult factory for
operation >50°C
–50 to 70°C
<2000m—consult factory for
operation >2000m
<95% noncondensing
Any
3
6000V
103 (46.8) with lugs
91 (41.4) without lugs
0.5–180 seconds (0.5–360
seconds extended ramp)
–30 to 50°C (no derating)
consult factory for
operation >50°C
<2000m—consult factory for
operation >2000m
S801V10
1000
11.03 (280.2)
16.57 (420.8)
7.23 (183.7)
10M
660V
3g
15g
200–600V
47–63 Hz
30–100%
5, 10, 20 and 30
2, 4 or 6
2/0 to 500 kcmil
Add-on lug kit
22–14
2 (or one AWG 12)
3.5
3.31
21.6–26.4
1.4
10
1%
240
120
3
–50 to 70°C
<95% noncondensing
Any
3
6000V

Related parts for S701G25N3S