XTAE007B10A001 EATON CUTLER HAMMER, XTAE007B10A001 Datasheet - Page 151

IEC Non-Reversing Starter

XTAE007B10A001

Manufacturer Part Number
XTAE007B10A001
Description
IEC Non-Reversing Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTAE007B10A001

No. Of Phases
Single Or Three
Power Rating
3.5kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Mounting Type
DIN Rail
Overload Adjustment Current Max
1A
Overload Adjustment Current Min
0.6A
Supply Voltage Max
120VAC
Frame Size
Standard
Technical Data and Specifications
Electronic Overload Relays up to 1500A
Description
Electrical Ratings
Operating voltage (three-phase) and frequency
FLA Range
Use with Contactors
XT IEC frames
Freedom NEMA sizes
Trip Class
Motor Protection
Thermal overload setting
Feature
Phase loss
Phase unbalance (selectable: enable/disable)
Ground fault (selectable: enable/disable)
Reset
Indicators
Trip status
Mode LED
Options
Remote reset
Reset bar
Communication expansion module
Communication adapter
Capacity
Load terminals
Input, auxiliary contact and remote reset terminals
Voltages
Insulation voltage U
Insulation voltage U
Rated impulse withstand voltage
Overvoltage category/pollution degree
Terminal capacity
Tightening torque
Terminal capacity
Tightening torque
i
i
(three-phase)
(control)
Volume 5—Motor Control and Protection CA08100006E—May 2011 www.eaton.com
Specification
45 mm
Range
690 Vac (60/50 Hz)
0.33–1.65A
1–5A
4–20A
9–45A
B, C, D
00, 0, 1, 2
10A, 10, 20, 30
Selectable
1.05 x FLA: does not trip
1.15 x FLA: overload trip
Range
Fixed threshold 50%
Fixed threshold 50%
50% of FLA dial setting
>150% = 2 sec
>250% = 1 sec
Manual/automatic
Orange flag
One flash: Overload operating properly
Two flashes: Current is above FLA dial setting—pending trip
Yes
Yes
Yes
Yes
12–10 AWG (4–6 mm
8–6 AWG (6–16 mm
20–25 lb-in (2.3–2.8 Nm)
25–30 lb-in (2.8–3.4 Nm)
2 x (18–12) AWG
5.3 lb-in (0.8–1.2 Nm)
690 Vac
500 Vac
6000 Vac
III/3
2
)
2
)
IEC Contactors and Starters
XT IEC Power Control
55 mm
Range
690 Vac (60/50 Hz)
20–100A
F, G
3
10A, 10, 20, 30
Selectable
1.05 x FLA: does not trip
1.15 x FLA: overload trip
Range
Fixed threshold 50%
Fixed threshold 50%
50% of FLA dial setting
>150% = 2 sec
>250% = 1 sec
Manual/automatic
Orange flag
One flash: Overload operating properly
Two flashes: Current is above FLA dial setting—pending trip
Yes
Yes
Yes
Yes
6–1 AWG (16–50 mm
25–30 lb-in (2.8–3.4 Nm)
2 x (18–12) AWG
5.3 lb-in (0.8–1.2 Nm)
690 Vac
500 Vac
6000 Vac
III/3
2
)
27.1
V5-T27-151