U2001A AGILENT TECHNOLOGIES, U2001A Datasheet

USB POWER SENSOR, 6GHZ, -60DBM To +20DBM

U2001A

Manufacturer Part Number
U2001A
Description
USB POWER SENSOR, 6GHZ, -60DBM To +20DBM
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of U2001A

Frequency Measuring Range
10MHz To 6GHz
Amplitude Accuracy
± 3%
Standing Wave Ratio
1.19
Connector Type
N
External Height
35.9mm
External Width
46mm
External Depth
163.75mm
Lead Free Status / RoHS Status
na
Agilent U2000 Series USB
Power Sensors
Data Sheet
The compact, low-cost
alternative to conventional
power measurement solutions

U2001A Summary of contents

Page 1

Agilent U2000 Series USB Power Sensors Data Sheet The compact, low-cost alternative to conventional power measurement solutions ...

Page 2

Why Agilent’s Power Meters and Sensors? Reliable, high-performing solutions Every power meter and sensor from Agilent consistently delivers great results. A sure investment for many years to come Code-compatibility between power meters reduces the need for re-coding. Not only that, ...

Page 3

Compact Solutions for Testing Today’s RF and Microwave Communication Systems For installation and maintenance of base stations • Lightweight and rugged • Simple set-up and usage • Portable with low power consumption • Wide dynamic and frequency ranges • Quick ...

Page 4

Introducing the U2000 Series USB Power Sensors The U2000 Series enable simpler, lower-cost power measurements versus conventional power meter and sensor combinations. Now with nine high-performance models, the U2000 Series USB power sensors offer com- pact, high-performance solutions for today’s ...

Page 5

Introducing the U2000 Series USB Power Sensors (continued) Faster production testing of multiple channels The U2000 Series’ fast measurement speed helps reduce test time. This, coupled with the capability to enable monitoring of more than 20 channels simultaneously ...

Page 6

Take a Closer Look Built-in triggering port for synchronization with external instruments or events Small and lightweight build Diode-based sensors frequently rely on the application of correction factors to extend their dynamic range beyond their square-law region, typi- cally in ...

Page 7

... MHz to 6 GHz U2002H 50 MHz to 24 GHz Maximum SWR Model Frequency range MHz 30 MHz to 2 GHz U2000A GHz GHz GHz MHz U2001A 30 MHz to 2 GHz GHz 50 MHz to 2 GHz GHz U2002A GHz GHz GHz 9 kHz to 2 GHz U2004A GHz 10 MHz to 2 GHz U2000B ...

Page 8

... Specifications (continued) Typical SWR for U2000A sensor (25 °C ± 10 °C) Typical SWR for U2001A sensor (25 °C ± 10 °C) Typical SWR for U2002A sensor (25 °C ± 10 °C) U2000A 1.12 1.10 1.08 1.06 1.04 1.02 1. Frequency GHz U2001A 1.12 1.10 1.08 1.06 1.04 1 ...

Page 9

Specifications (continued) U2004A 1.12 1.10 1.08 1.06 1.04 1.02 1. Frequency GHz Typical SWR for U2004A sensor (25 °C ± 10 °C) U2000H 1.12 1.10 1.08 1.06 1.04 1.02 1. Frequency GHz ...

Page 10

... The accuracy for – dBm (U2000/1/2A +11 dBm (U2000/1/2H), and +23 to +31 dBm (U2000/1B) power level will be dominated by zero set and measurement noise. For overall accuracy, refer to the measurement uncertainty calculator which is available on the Agilent Technologies Web site. ...

Page 11

Specifications (continued) Typical power accuracy at 25 °C for U2000/1/2/4A sensors 1 Typical power accuracy at 25 °C for 1 U2000/1B sensors Typical power accuracy at 25 °C for 1 U2000/1/2H sensors 1. Measurement uncertainty ≤ 1.6%. At room temperature ...

Page 12

Specifications (continued) Zero and measurement noise Average only Mode 1 Power range Zero set (internal) U2000/1/2/4A –60 to –35 dBm ± 1.5 nW (±2.8 nW for U2004A) –38 to –15 dBm ± (±3 nW for U2004A) –20 to ...

Page 13

Specifications (continued) Effect of time-gating and averaging on normal mode measurement noise: The normal mode measurement noise wil depend on the gate length (time-gated period in second) and the number of averages. The noise can be approximately calculated with the ...

Page 14

Specifications (continued) Settling time Manual filter, 10-dB decreasing power step (not across switching points) Number of averages 1 Settling time (s) Normal speed 0.045 x2 speed 0.042 Auto filter, default resolution, 10-dB decreasing power step x2 Normal speed speed 45 ...

Page 15

... Frequency Uncertainty (%) (25 °C ± 10 °C) U2000A sensor MHz 1.8 30 MHz to 2 GHz 1 GHz 2 GHz 2 GHz 2.2 U2001A sensor MHz 1.8 30 MHz to 2 GHz 1 GHz 2.0 U2002A sensor 50 MHz to 2 GHz 2 GHz 2 GHz 2 GHz 2 ...

Page 16

Specifications (continued) Trigger Internal trigger Resolution Level accuracy Jitter External TTL trigger input Impedance Trigger low Trigger high Minimum trigger pulse width Minimum trigger repetition period Trigger latency Trigger delay Range Resolution Trigger hold-off Range Resolution Trigger hysteresis Range Resolution ...

Page 17

Specifications (continued) General specifications Physical characteristics Dimensions (LxWxH) Weight Operating environment Temperature Humidity Altitude Pollution Storage and shipment Environment Temperature Humidity Altitude Pollution Other Current requirement Connector Cable Programmability Safety and EMC compliance Calibration 1 1 Warranty Compatible instruments 1. ...

Page 18

Using the U2000 Series with the N1918A Power Analysis Manager The N1918A software is available in two versions: the basic Power Panel and advanced Power Analyzer. Power Analyzer provides full access to the software’s complete features and capabilities and its ...

Page 19

Using the U2000 Series with the N1918A Power Analysis Manager (continued) (continued) Save/Load file functions Save measurement data (with timestamp) Load measurement data Data recording 2 (with timestamp) Instrument settings options Save and restore instrument setting Time-gated measurements Instrument preset ...

Page 20

Using the U2000 Series with the N1918A Power Analysis Manager (continued) System requirements Hardware Processor RAM Hard disk space Resolution Operating system and browser Operating system Browser Software Agilent IO Libraries Suite Microsoft .NET Framework Microsoft Visual C++ 2005 Runtime ...

Page 21

... With 1K ohms input trigger impedance. Higher impedance is typically required when several instruments’ input trigger ports are connected in parallel for triggering purpose. Standard option has 50 ohms input trigger impedance. U2001A-H25 U2001A sensor with extended power range, -60 dBm to +25 dBm U2002A-H26 U2002A sensor with extended frequency range, 10 MHz to 26.5 GHz Standard-shipped accessories Trigger cable BNC Male to SMB female 50 Ω ...

Page 22

Ordering Information (continued) Accessories, calibration and documentation options Cables U2031A U2031B U2031C U2032A Travel kits U2000A-201 U2000A-202 U2000A-204 Hanging kit U2000A-203 Calibration Option 1A7 Option A6J Warranty Option R-51B-001-3C Option R-51B-001-5C Documentation Option OB1 Option ABD Option ABE Option ABF ...

Page 23

... Spain 34 (91) 631 3300 Sweden 0200- Switzerland 0800 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: July 8, 2010 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2010 Printed in USA, September 9, 2010 5989-6278EN ...