SGTL5000XNAA3R2 Freescale, SGTL5000XNAA3R2 Datasheet - Page 50

no-image

SGTL5000XNAA3R2

Manufacturer Part Number
SGTL5000XNAA3R2
Description
Manufacturer
Freescale
Datasheet

Specifications of SGTL5000XNAA3R2

Single Supply Voltage (typ)
1.8/2.5/3.3V
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SGTL5000XNAA3R2
Manufacturer:
FREESCALE
Quantity:
11 450
Part Number:
SGTL5000XNAA3R2
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
SGTL5000XNAA3R2
0
Company:
Part Number:
SGTL5000XNAA3R2
Quantity:
30 000
Table 38. DAP_CONTROL 0x0100
50
SGTL500
FUNCTIONAL DEVICE OPERATION
PROGRAMMING EXAMPLES
BITS
BITS
15:5
15
3:2
1:0
3:1
4
0
14
MODE_CM
MODE_LR
DAP_EN
MIX_EN
FIELD
FIELD
RSVD
RSVD
13
12
RW
RW
RW
RW
RW
RW
RO
RO
11
RSVD
RESET
RESET
10
0x0
0x0
0x0
0x0
0x0
0x0
9
Reserved
Enable/Disable the DAP mixer path
0x0 = Disable
0x1 = Enable
When enabled, DAP_EN must also be enabled to use the mixer.
Reserved
Enable/Disable digital audio processing (DAP)
0x0 = Disable. When disabled, no audio will pass-through.
0x1 = Enable. When enabled, audio can pass-through DAP even if none of the DAP
functions are enabled.
These bits control the behavior of the short detector for the capless headphone central
channel driver. This mode should be set prior to powering up the headphone amplifier.
When a short is detected the amplifier output switches to classA mode internally to
avoid excessive currents.
0x0 = Disable short detector, reset short detect latch, software view non-latched short
signal
0x1 = Enable short detector and reset the latch at timeout (every ~50 ms)
0x2 = This mode is not used/invalid
0x3 = Enable short detector with only manual reset (have to return to 0x0 to reset the
latch)
These bits control the behavior of the short detector for the capless headphone central
channel driver. This mode should be set prior to powering up the headphone amplifier.
When a short is detected the amplifier output switches to classA mode interally to avoid
excessive currents.
0x0 = Disable short detector, reset short detect latch, software view non-latched short
signal
0x1 = Enable short detector and reset the latch at timeout (every ~50 ms)
0x2 = Enable short detector and auto reset when output voltage rises (preferred mode)
0x3 = Enable short detector with only manual reset (have to return to 0x0 to reset the
latch)
8
7
6
5
DEFINITION
DEFINITION
MIX_EN
4
Analog Integrated Circuit Device Data
3
Freescale Semiconductor
RSVD
2
1
DAP_EN
0

Related parts for SGTL5000XNAA3R2