AD2S1200WSTZ Analog Devices Inc, AD2S1200WSTZ Datasheet - Page 10

IC R/D CONV W/REF OSCIL 44-LQFP

AD2S1200WSTZ

Manufacturer Part Number
AD2S1200WSTZ
Description
IC R/D CONV W/REF OSCIL 44-LQFP
Manufacturer
Analog Devices Inc
Type
R/D Converterr
Datasheet

Specifications of AD2S1200WSTZ

Resolution (bits)
12 b
Data Interface
Serial, Parallel
Voltage Supply Source
Analog and Digital
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
44-LQFP
Input Channel Type
Differential
Supply Voltage Range - Analog
4.75V To 5.25V
Supply Voltage Range - Digital
4.75V To 5.25V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-AD2S1200CBZ - BOARD EVAL FOR AD2S1200
Sampling Rate (per Second)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD2S1200WSTZ
Manufacturer:
Analog Devices Inc
Quantity:
135
Part Number:
AD2S1200WSTZ
Manufacturer:
ADI
Quantity:
276
Part Number:
AD2S1200WSTZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
AD2S1200
Signal Degradation Detection
Degradation of signal (DOS) is detected when either resolver
input (Sin or Cos) exceeds the specified DOS Sin/Cos threshold
by comparing the monitor signal to a fixed maximum value.
DOS is also detected when the amplitude of the input signals
Sin and Cos mismatch by more than the specified DOS Sin/
Cos mismatch by continuously storing the minimum and
maximum magnitude of the monitor signal in internal registers,
and calculating the difference between the minimum and
maximum. DOS is indicated by a logic low on the DOS pin, and
is not latched when the input signals exceed the maximum
input level. When DOS is indicated due to mismatched signals,
the output is latched low until a rising edge of SAMPLE resets
the stored minimum and maximum values. The DOS condition
has priority over the LOT condition, as shown in Table 4. DOS
is indicated within 30° of angular output error worst case.
Loss of Position Tracking Detection
Loss of tracking (LOT) is detected for three separate conditions:
LOT is indicated by a logic low on the LOT pin, and is not
latched. LOT has a 4° hysteresis, and is not cleared until the
internal error signal or internal/external position mismatch is
less than 1°. When the maximum tracking rate is exceeded, LOT
is cleared when both the velocity is less than 1,000 rps and the
internal/external position mismatch is less than 1°. LOT can be
indicated for step changes in position (such as after a RESET
signal is applied to the AD2S1200), or for accelerations
>~85,000 rps
tracking converter is functioning properly. The LOT condition
has lower priority than both the DOS and LOS conditions as
shown in Table 4. The LOT and DOS conditions cannot be
indicated at the same time.
Table 4. Fault Detection Decoding
Condition
Loss of Signal
Degradation of Signal
Loss of Tracking
No Fault
When the internal error signal of the AD2S1200 has
exceeded 5°
When the input signal exceeds the maximum tracking rate
of 60,000 rpm (1,000 rps)
When the internal position (at the position integrator)
differs from the external position (at the position register)
by more than 5°
2
. LOT is useful as a built-in test (BIT) that the
DOS
0
0
1
1
LOT
0
1
0
1
Priority
1
2
3
Rev. 0 | Page 10 of 24
Responding to a Fault Condition
If any fault condition (LOS, DOS, or LOT) is indicated by the
AD2S1200, the output data must be presumed to be invalid.
This means that even if a RESET or SAMPLE pulse releases the
fault condition, the output data may be corrupted, even though
a fault may not be immediately indicated after the RESET /
SAMPLE event. As discussed earlier, there are some fault
conditions with inherent latency. If the device fault is cleared,
there could be some latency in the resolver’s mechanical
position before the fault condition is re-indicated.
When a fault is indicated, all output pins will still provide data,
although the data may or may not be valid. The fault condition
will not force the parallel, serial, or encoder outputs to a known
state. However, a new startup sequence is recommended only
after a LOS fault has been indicated.
Response to specific fault conditions is a system-level
requirement. The fault outputs of the AD2S1200 indicate that
the device has sensed a potential problem with either the
internal or external signals of the AD2S1200. It is the
responsibility of the system designer to implement the
appropriate fault-handling schemes within the control hardware
and/or algorithm of a given application based on the indicated
fault(s) and the velocity or position data provided by the
AD2S1200.
False Null Condition
Resolver-to-digital converters that employ Type II tracking
loops based on the error equation (Equation 3) presented in the
Principle of Operation section can suffer from a condition
known as “false null. ” This condition is caused by a metastable
solution to the error equation when θ − ϕ = 180°. The
AD2S1200 is not susceptible to this condition because its
hysteresis is implemented externally to the tracking loop.
Because of the loop architecture chosen for the AD2S1200, the
internal error signal always has some movement (1 LSB per
clock cycle), and so, in a metastable state, the converter will
always move to an unstable condition within one clock cycle,
causing the tracking loop to respond to the false null condition
as if it were a 180° step change in input position (the response
time is the same as specified in Dynamic Performance section
of Table 1). Therefore, it is impossible to enter the metastable
condition any time after the startup sequence as long as the
resolver signals are valid. However, in a case of a loss of signal, a
full reset is recommended to avoid the possibility of a false null
condition. The response to the false null condition has been
included in the value of t
Sequencing and Reset section.
TRACK
provided in the Supply

Related parts for AD2S1200WSTZ