X9418WV24Z-2.7 Intersil, X9418WV24Z-2.7 Datasheet - Page 5

no-image

X9418WV24Z-2.7

Manufacturer Part Number
X9418WV24Z-2.7
Description
IC XDCP DUAL 64TAP 10K 24-TSSOP
Manufacturer
Intersil
Series
XDCP™r
Datasheet

Specifications of X9418WV24Z-2.7

Taps
64
Resistance (ohms)
10K
Number Of Circuits
2
Temperature Coefficient
300 ppm/°C Typical
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Resistance In Ohms
10K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
X9418WV24Z-2.7
Manufacturer:
Intersil
Quantity:
31
Figure 2. Instruction Byte Format
The four high order bits define the instruction. The
next two bits (R1 and R0) select one of the four
registers that is to be acted upon when a register
oriented instruction is issued. The last bits (P0) select
which one of the two potentiometers is to be affected
by the instruction. Bit 1 is defined to be 0.
Four of the nine instructions end with the transmission
of the instruction byte. The basic sequence is
illustrated in Figure 3. These two-byte instructions
exchange data between the wiper counter register and
one of the data registers. A transfer from a Data
Register to a Wiper Counter Register is essentially a
write to a static RAM. The response of the wiper to this
action will be delayed t
counter register (current wiper position), to a Data
Register is a write to nonvolatile memory and takes a
minimum of t
between one of the two potentiometers and one of its
Figure 3. Two-Byte Instruction Sequence
I3
Instructions
SCL
SDA
I2
WR
I1
to complete. The transfer can occur
S
T
A
R
T
I0
WRL
0
Register
5
R1
. A transfer from the wiper
Select
1
R0
0
1
0
Register Select
Wiper Counter
A3 A2 A1 A0
P0
X9418
A
C
K
I3
associated registers; or it may occur globally, wherein
the
potentiometers and one of their associated registers.
Four instructions require a three-byte sequence to
complete. These instructions transfer data between
the host and the X9418; either between the host and
one of the Data Registers or directly between the host
and the wiper counter register. These instructions are:
Read Wiper Counter Register (read the current wiper
position of the selected pot), write Wiper Counter
Register (change current wiper position of the selected
pot), read Data Register (read the contents of the
selected nonvolatile register) and write Data Register
(write a new value to the selected Data Register). The
sequence of operations is shown in Figure 4.
The Increment/Decrement command is different from
the other commands. Once the command is issued
and the X9418 has responded with an acknowledge,
the master can clock the selected wiper up and/or
down in one segment steps; thereby, providing a fine
tuning capability to the host. For each SCL clock pulse
(t
move one resistor segment towards the V
terminal. Similarly, for each SCL clock pulse while
SDA is LOW, the selected wiper will move one resistor
segment towards the V
illustration of the sequence and timing for this
operation are shown in Figures 5 and 6 respectively.
HIGH
I2
transfer
) while SDA is HIGH, the selected wiper will
I1
I0
R1 R0 0
occurs
P0
L
between
/R
L
A
C
K
terminal. A detailed
S
T
O
P
both
October 12, 2006
of
FN8194.3
H
/R
the
H