F3SJA0815P20 Omron, F3SJA0815P20 Datasheet - Page 63

no-image

F3SJA0815P20

Manufacturer Part Number
F3SJA0815P20
Description
Manufacturer
Omron
Datasheet

Specifications of F3SJA0815P20

Lead Free Status / Rohs Status
Compliant
When four muting sensors are connected
* The output operation mode for auxiliary output 1 is control output data/inverse of control output signals enabled (default setting).
Note: Start interlock and restart interlock can be used with a setting tool.
The muting function can be used by attaching the F39-CN6 Key Cap.
Muting sensor
Workpiece
(PNP output)
Reflector
A1
B1
F39-JC@A-L
Emitter
F3SJ
A2
Muting lamp
(external indicator)
B2
Communication
Communica-
tion line ( )
line (+)
(Gray)
(Pink)
F39-JC@A-D
KM1
KM2
+24 VDC
PLC
Receiver
0V
IN
KM1 KM2
KM1, KM2 N.O. contact
KM1, KM2 N.C. contact
E1
F3SJ Control output
• Auto reset mode
• Using external device monitoring function
S1:
S2:
KM1, KM2: Safety relay with forcibly-guided contacts
KM3:
M:
E1:
PLC:
A1, B1, A2, B2, Muting sensor: Retro-reflective
A1 Control output
B1 Control output
A2 Control output
B2 Control output
OUT
Muting input 1
Muting input 2
PLC input *
PLC output
Light interrupted
External test switch (connect to 0 V if the
switch is not necessary.)
Lockout reset switch (connect to 24 V if the
switch is not necessary.)
(G7SA) or magnetic contactor
Solid state contactor (G3J)
3-phase motor
24 VDC power supply (S82K)
Programmable controller
(Used for monitoring -- not related to safety
system)
photoelectric sensor (E3Z-R81)
Light incident
Timing Chart
M
F3SJ Ver.2
KM1
KM2
KM3
63